7. Trouble Shooting
Having trouble?
Noise is louder than specifications.
Nothing appears in the wireless remote controller display, the display
is faint, or signals are not received by the indoor unit unless the remote
controller is close.
The operation lamp near the receiver for the wireless remote controller on
the indoor unit is blinking.

8. Specifications

Model
Power source
∙ Voltage/Frequency
Rated Input
∙ Cooling/Heating indoor only
Rated Current
∙ Cooling/Heating indoor only
Heater
Height dimension
Width dimension
Depth dimension
Fan airflow rate
∙ Low-Middle2-Middle1-High
Noise level
∙ Low-Middle2-Middle1-High
Net weight
*1. The figure in ( ) indicates standard Grille's.
16
PLA-A12EA7
<V / Hz>
<kW>
0.02/0.02
<A>
0.26/0.21
<kW>
<inch>
<inch>
<inch>
<m
/ min>
12-13-14-15
3
<dB>
27-28-29-30
<lbs>
46 (11)
Here is the solution. (Unit is operating normally.)
The indoor operation sound level is affected by the acoustics of the
particular room as shown in the following table and will be higher than
the noise specification, which was measured in anechoic room.
absorbing rooms
Location
examples
Noise levels
The batteries are low.
Replace the batteries and press the Reset button.
If nothing appears even after the batteries are replaced, make sure that
the batteries are installed in the correct directions (+, –).
The self diagnosis function has operated to protect the air conditioner.
Do not attempt to repair this equipment by yourself.
Turn off the power switch immediately and consult your dealer. Be sure
to provide the dealer with the model name.
PLA-A18EA7
PLA-A24EA7
Single 208/230/60
0.03/0.03
0.05/0.04
0.34/0.29
0.49/0.44
10-3/16 (1-9/16)
33-1/16 (37-3/8)
33-1/16 (37-3/8)
13-14-16-17
15-18-20-23
28-29-31-32
28-30-33-36
High sound
Normal rooms
Broadcasting
Reception room,
studio, music
hotel lobby, etc.
room, etc.
3 to 7 dB
6 to 10 dB
PLA-A30EA7
PLA-A36EA7
0.06/0.05
0.10/0.09
0.59/0.54
0.98/0.93
11-3/4 (1-9/16)
15-18-20-25
19-24-29-34
28-32-35-38
32-37-41-44
56 (11)
Low sound
absorbing rooms
Office, hotel
room
9 to 13 dB
PLA-A42EA7
0.11/0.10
1.05/1.00
21-26-30-34
34-38-42-45