26
www.electrolux.com
Minimum distances
Dimension
A
B
C

14.2 Technical data

Voltage
Appliance category:
Gas original:
14.4 Bypass diameters
BURNER
Auxiliary
Semi-rapid
Triple Crown
1) Type of bypass depends on model.
14.5 Gas burners for LPG G30 30 mbar
BURNER
Triple Crown
Semi-rapid
Auxiliary
14.6 Gas connection
Use a fixed connections or use a flexible
stainless steel pipes in compliance with
the regulation in force. If you use flexible
metallic pipes, make sure they do not
come in touch with mobile parts and they
are not squeezed.
mm
400
650
150
220 - 240 V
NORMAL
REDUCED
POWER kW
POWER kW
4.0
2.0
1.0
Frequency
Appliance class
Dimension
Height
Width
Depth
14.3 Other technical data
I3B/P
G30 30 mbar
Ø BYPASS
INJECTOR
MARK 1/100
mm
1.80
101
0.43
71
0.35
50
50 / 60 Hz
1
mm
855
600
600
1)
1/100 mm
29 / 30
32
67
NOMINAL GAS
FLOW g/h
291
145
73

Hide quick links: