Loop Test; Error Codes Loop Test - Yamaha DVD-S520 Service Manual

Hide thumbs Also See for DVD-S520:
Table of Contents

Advertisement

DVD-S520/DV-S5450

4. LOOP TEST

At the start of the loop test, the display will show the result
of the interactive player test:
The left side of the display contains a 3-digit code, which
can have a value between 000 and 111. These values are
to be interpreted as follows:
Displayed
Indication for each module
Value
Basic Engine
000
ok
001
ok
010
ok
011
ok
100
faulty
101
faulty
110
faulty
111
faulty

ERROR CODES LOOP TEST

ERROR CODE
0601
0901
1104
1102
1103
1104
1201
1202
1203
1204
1301
1302
1303
1304
1601
5201
5202
5203
5204
5401
5402
5403
5403
17
Figure 28
Mono
Display
PCB
PCB
ok
ok
ok
faulty
faulty
ok
faulty
faulty
ok
ok
ok
faulty
faulty
ok
faulty
faulty
Figure 29
NUCLEUS NUMBER ERROR DESCRIPTION
6
9
11
12
13
16
52
54
The loop test will perform the same nuclei as the dealer
test, but it will loop through the list of nuclei indefinitely.
The display of the DVD player will display not only the
three digits indicating correct/faulty modules and the last
found error code (as mentioned, faults are detected as far
as they can be within the scope of the diagnostic
software), but also a loop counter indicating how many
times the loop has been gone through.
Example:
FAULTY
MODULE(S)
The number after the hyphen indicates the number of
times the loop test has been performed; the 4 digits at the
right side of the display show the last error that was found
when running the loop test: the leftmost two digits of this
code indicate which nucleus resulted in a fault; the
rightmost two digits refer to the faultcode within that
nucleus. For further explanation of this error code, see list
of error codes below.
Calculated checksum of FLASH is not correct
The DVD DRAM is faulty
I2C bus busy before start
NVRAM access time-out
No NVRAM Acknowledge
NVRAM reply time-out
I2C bus busy
I2C bus not working
Slave controller not responding
Slave response is not correct
Parity error from basic engine to serial
Parity error from serial to basic engine
No communication between serial and basic engine
Communication time-out error
The SDRAM is faulty
I2C bus busy
Error sending I2C command to COLOR SETUP IC
Colour setup IC not responding
Colour setup IC response is not correct
I2C bus busy
Error sending I2C command to SCART SWITCH IC
SCART Switch is not responding
SCART Switch response is not correct
Figure 31
LOOP
COUNTER
NUCLEUS
ERROR
Figure 30