6.3 Remove the rear wall

Remove the tank lid.
Remove the rear wall (2 screws).
Replace the tank lid.
1 Screws
2 Reservoir cover

6.4 Settings, burner

Note
An accurate basic adjustment of the burner is only
possible if the heating coil was previously thoroughly
desooted and the deposits were removed.Eine ex-
akte Grundeinstellung des Brenners ist nur möglich,
wenn die Heizschlange vorher gründlich entrußt und
die inneren Ablagerungen entfernt wurden.
Measure water temperature
Install the shut-off valve with thermometer (special
tool) on the appliance outlet.
Switch on the burner and bring the appliance to
working pressure with full water volume via the
shut-off valve.
Measure the increase in water temperature (water
outlet temperature minus water supply flow tem-
perature).
For target values refer to technical specifications.
Measure the air pressure on the burner cover
(special tool) and adjust it on the air slider.
For target values refer to technical specifications.
Measure the soot value, CO2 content and the ex-
haust temperature (special tools, measuring
gauges).
Adjusting the fuel pressure
Set the fuel pressure (and water temperature) via
the set screw.
For target values refer to technical specifications.
Adjusting the soot value
If the soot value is too high, then the air slider
needs to be opened further or the fuel pressure
needs to be reduced.
Adjusting the CO2 value
Adjust the CO2 value by moving the air slider.
Open the air slider, the CO2 content will decrease.
1 Stop screw, air volume adjustment
2 Slider, air volume adjustment
3 Fuel pump
4 Hexagon head screwdriver
English 5.906-487.0 Rev. 00 (04/10)