Binary Chart Service Mode Tests - GE HTW200ASK_WW Technical Service Manual

Ge 27 inch top load washer
Hide thumbs Also See for HTW200ASK_WW:
Table of Contents

Advertisement

Binary Chart Service Mode Tests

Explaining Binary Code Service Mode Tests
Display Service Mode Test Chart).
Once in the Service Mode, rotate the Cycle Select knob to advance to the desired test.
Example:
status LEDs are lit.
Add the numbers of the lit LEDs together.
1 + 2 + 4 + 8 = 15 So it is in Test 15. Press and
release the Start button to enter the test.
Example: Test 10: Going from right to left, the second
and forth cycle status LEDs are lit.
Add the numbers of the lit LEDs together.
2 + 8 = 10 So it is in test 10. Press and release
the start button to enter the test.
Fault/Test #
displayed on
7-segment display
Binary Display Service Mode Test Chart
When entered into service
mode
Service Mode Tests
0
All LEDs on
1
Fault Codes
2
Personality ID
3
UI Software Version (Critical)
4
UI Software Version (Non-critical)
5
XML Version (Non-critical)
6
Hot Water Valve
7
Cold Water Valve
8
Fabric Softener Dispenser
9
Spray Rinse Valve
10
Pressure Sensor
11
Recirculate Pump
12
Drain Pump
13
Lid Switch
14
Spin
15
Agitate
16
Clear all Fault Codes
17
Change Personality
18
Analog Knob
32 16
32 16
Fault/Test # displayed in
binary format using cycle
status lights
Filled circles indicate light on
– 34 –
8
4
2
1
8
4
2
1

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents