Self-Diagnosis Code Table - Sony DSC-H50 Service Manual

Hide thumbs Also See for DSC-H50:
Table of Contents

Advertisement

1-2-3. Self-diagnosis Code Table

Self-diagnosis Code
Block
Detailed
Function
Code
C
1
3
0
C
3
2
0
E
6
1
0
E
6
1
1
E
6
2
0
E
6
2
1
E
6
2
1
E
6
2
1
E
6
2
2
E
9
1
0
E
9
2
0
Note: After repair, be sure to perform "1-3. PROCESS AFTER FIXING FLASH ERROR".
DSC-H50_L2
Symptom/State
The internal memory has experienced a
format error.
"Memory Stick Duo" is unformatted.
1
"Memory Stick Duo" is broken.
"Memory Stick Duo" type error
The camera cannot read or write data
on the "Memory Stick Duo".
1
Trouble with hardware
Difficult to adjust focus
0
(Cannot initialize focus)
Zoom operations fault
0
(Cannot initialize zoom lens.)
2
Abnormality of IC for steadyshot.
0
Lens initializing failure.
1
Lens overheating (PITCH).
2
Lens overheating (YAW).
0
Abnormality of thermistor.
1
Abnormality when flash is being charged.
0
Non-standard battery is used.
Format the internal memory.
Format the "Memory Stick Duo".
Insert a new "Memory Stick Duo".
Insert a supported "Memory Stick Duo".
Turn the power off and on again, or taking out and inserting the
"Memory Stick Duo" several times.
Turn the power off and on again.
Retry turn the power on by the power switch. If it does not
recover, check the focus reset sensor of lens block (pin wj of
CN401 on the SY-201 board). If it is OK, check the focus motor
drive IC (IC401 on the SY-201 board).
Retry turn the power on by the power switch. Check the zoom
reset sensor of lens block (pin qj of CN401 on the SY-201
board), if zooming is performed when the zoom button is
operated. If it is OK, check the zoom motor drive IC (IC401 on
the SY-201 board).
Check or replacement of the IC for steadyshot (IC503 on the SY-
201 board).
Check or replacement of the IC for steadyshot (IC503 on the SY-
201 board).
Check the HALL element (PITCH) of optical image stabilizer
(pin eg, ej of CN401 on the SY-201 board). If it is OK, check
PITCH/YAW angular velocity sensor (SE502 on the SY-201
board) peripheral circuits.
Check the HALL element (YAW) of optical image stabilizer (pin
e;, es of CN401 on the SY-201 board). If it is OK, check
PITCH/YAW angular velocity sensor (SE501 on the SY-201
board) peripheral circuits.
Replacement of lens block.
Checking of flash unit or replacement of flash unit. (Note)
Use the compatible battery only.
1-2