TECHNICAL INFORMATION

Serial Number Location
Record the engine serial number in the
space below. You will need this
information when ordering parts and
when making technical or warranty
inquiries.
SERIAL NUMBER &
ENGINE TYPE LOCATION
Engine serial number: __ __ __ __ — __ __ __ __ __ __ __
Engine type: ___ ___ ___ ___
Date Purchased: ______ / ______ / ______
Battery Connections for Electric Starter (applicable types)
Recommended Battery
GX240
12 V -14 Ah ~ 12 V - 30 Ah
GX270
GX340
12 V -18 Ah ~ 12 V - 30 Ah
GX390
Be careful not to connect the battery in reverse polarity, as this will
short circuit the battery charging system. Always connect the
positive (+) battery cable to the battery terminal before connecting
the negative (-) battery cable, so your tools cannot cause a short
circuit if they touch a grounded part while tightening the positive
(+) battery cable end.
A battery can explode if you do not follow the correct
procedure, seriously injuring anyone nearby.
Keep all sparks, open flames, and smoking materials
away from the battery.
WARNING: Battery posts, terminals, and related accessories
contain lead and lead compounds. Wash hands after handling.
1. Connect the battery positive (+) cable to the starter solenoid
terminal as shown.
2. Connect the battery negative (-) cable to an engine mounting
bolt, frame bolt, or other good engine ground connection.
3. Connect the battery positive (+) cable to the battery positive
(+) terminal as shown.
4. Connect the battery negative (-) cable to the battery negative
(-) terminal as shown.
5. Coat the terminals and cable ends with grease.
NEGATIVE (-)
BATTERY CABLE
16
ELECTRIC STARTER
(applicable types)
STARTER
SOLENOID
POSITIVE ( + ) BATTERY CABLE
Remote Control Linkage
The throttle and choke control levers are provided with holes for
optional cable attachment. The following illustrations show
installation examples for a solid wire cable and for a flexible,
braided wire cable. If using a flexible, braided wire cable, add a
return spring as shown.
It is necessary to loosen the throttle lever friction nut when
operating the throttle with a remote-mounted control.
REMOTE THROTTLE LINKAGE
THROTTLE LEVER
FRICTION NUT
Flexible wire core
mounting
WIRE
5 mm
CIRCLIP
Solid wire core
mounting
REMOTE CHOKE LINKAGE
4 mm SCREW
WIRE
5 mm CIRCLIP
ENGLISH
4 mm SCREW
WIRE HOLDER
OPTIONAL
THROTTLE
LEVER
WIRE HOLDER