Switch Settings On The Board/Functions Of Leds - Sony DFR-E3000 Maintenance Manual

Sdds recorder system digital film sound encoder
Hide thumbs Also See for DFR-E3000:
Table of Contents

Advertisement

1-1. Installation
1-1-7. Switch Settings on the Board/
Functions of LEDs
DPR-139 board
F
E
D
C
B
S600
A
D501 - D508
1
2
3
Switches
S301:
Internal signal monitor selection
(for CL331 to CL346)
Factory setting: "0"
S302 (S302-1 to -8)
S302-1:
Test switch
ON: SCRAMBLE OFF
OFF: SCRAMBLE ON
S302-2 to -8: Unused
Do not change the factory setting
Factory setting:
S302-1:
S302-2 to -4: ON
S302-5 to -8: OFF
S501 (S501-1 to -8)
S501-1: LIP TEST mode setting
ON: Normal mode
OFF: Test (lip sync adjustment) mode
1-12
S502
S301
S302
S605
S604
CN701
S601
S603
S602
4
5
6
D101
D202 D302 D102 D203,
D303
D301
A side (Component side)
ON
S501-2: SYS CTRL setting
Switches the single operation and PC
connection operation modes.
ON: Single operation
OFF: PC connection operation
S501-3: Digital display LED mode selection
ON: TC and FG time displays
OFF: SYS display
S501-4: Test mode (Design switch)
S501-5: Test mode (Design switch)
S501-6: Digital display LED mode selection
ON: TC display
OFF: FG display
Enabled when switch S501-3 is ON.
S501-7: Test mode (Design switch)
S501-8: CLK test mode (Design switch)
Factory setting:
S501-1 to -3: ON
S501-4 to -8: OFF
S502 (S502-1, -2)
S502-1: VIDEO SYNC OUT voltage setting
ON: 0.3 V p-p
OFF: 4 V p-p
S502-2: CAMERA SYNC OUT voltage setting
ON: 0.3 V p-p
OFF: 4 V p-p
Factory setting:
S502-1: OFF
S502-2: OFF
S600:
System reset
Initializes the DFR-E3000.
S601:
Unused. (Used in the OFF state.)
S602:
Unused. (Used in the OFF state.)
S603:
Unused. (Used in the OFF state.)
S604:
Switches the LED display ON/OFF of the DFR-
E3000.
Right: The LED display goes off.
Left: The LED display goes on.
Factory setting:
Left (The LED display goes on.)
S605:
Single operation mode setting
Used at the factor setting.
Factory setting: "0"
DFR-E3000

Advertisement

Table of Contents
loading

Table of Contents