RespirAide 300T Operation Manual

Electronic air purifier
Hide thumbs Also See for 300T:

Advertisement

TUV
PRODUCT SERVICE
NRTL
ERI JU07655-7001
US
ISO 9001:2000
Sensor
Manual
Auto
Remote control
Timer
Filter & UV lamp
Safety switch
replacement alarm
Button melody
Check alarm
Phas e
ELECTRONIC AIR PURIFIER

Operation Manual

Model No. RespirAide 300T
WARNING
Before operating the system, please read
this manual thoroughly, and retain it for
future reference.
This unit cannot be used in atmosphere
containing explosive dust, gas or oxygen,or
in an area where flammable dust is present.
If so, it may result in explosion or fire!
This product can be used only where the
power supply is 120V/60Hz. You cannot
use the unit if the power voltage is different.
RespirAide Tech Inc.
13-100 Hanlan Road
Woodbridge, Ontario Canada
L4L 4V8
Tel: 1-866-874-2532
Fax: 1-905-850-5553
www.respiraide.com
R
**RespirAide is a trademark of RespirAide Tech Inc.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 300T and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for RespirAide 300T

  • Page 1: Operation Manual

    RespirAide Tech Inc. Sensor 13-100 Hanlan Road Button melody Manual Auto Remote control Woodbridge, Ontario Canada L4L 4V8 Tel: 1-866-874-2532 Fax: 1-905-850-5553 Timer Filter & UV lamp Safety switch Check alarm replacement alarm www.respiraide.com **RespirAide is a trademark of RespirAide Tech Inc.
  • Page 2: Table Of Contents

    BEFORE OPERATING, READ ALL INSTRUCTIONS IN THIS MANUAL CAREFULLY. CONTENTS FOR CUSTOMER ASSISTANCE ........CONSUMER LIMITED WARRANTY ......HOW IT WORKS ............FEATURES AND SPECIFICATIONS ......IMPORTANT SAFETY PRECAUTIONS E-8~11 ......Warning ......................Cautions Concerning Operation PART NAMES AND DESCRIPTION ......
  • Page 3: For Customer Assistance

    FOR CUSTOMER ASSISTANCE If you have questions about your air purifier, call the customer service number. Before calling, please note the model and serial number located on the back of the unit and fill in the following information below. This information will help us answer your questions much more quickly.
  • Page 4: Consumer Limited Warranty

    LIMITED WARRANTY Congratulations on your investment RespirAide Tech Inc. (hereinafter called RTI) gives you the following limited warranty for this product only if it was originally purchased from RTI or from an Authorized RTI Dealer. RTI warrants that this product is free, under normal use and maintenance, from any defects in material and workmanship.
  • Page 5: How It Works

    HOW IT WORKS The air purifier functions as an air cleaner by helping to disinfect airborne microorganisms and removing particulates from the air. The centrifugal fans of the unit draw air through the front panel (Intake) on the front of the unit. Then it passes through the Pre-filter, the Electrostatic precipitator, the Activated Carbon Filter and the UV-Photo catalytic sterilization chamber.
  • Page 6: Features And Specifications

    No screws, hooks or tools are required. The electronic cell captures small particles on aluminum plates that are simply rinsed off in the sink. There are no expensive filters to replace. Specifications Model No. RespirAide 300T Power Requirement 120V, 60Hz, 0.71A Rated Power...
  • Page 7: Important Safety Precautions

    -Remove the power plug from the wall outlet before cleaning the unit and when not using the unit. Turn off all controls before unplugging. -If the power cord is damaged, it must be replaced by the manufacturer, its service agent, RespirAide authorized service or similarly qualified person.
  • Page 8 IMPORTANT SAFETY PRECAUTIONS This manual classifies precautions into WARNINGS and CAUTIONS. Be sure to follow all precautions below: They are important for ensuring your safety. WARNING CAUTION If you do not follow these instructions If you do not follow these instructions   ...
  • Page 9 IMPORTANT SAFETY PRECAUTIONS DO NOT wash or reuse the activated carbon The activated carbon filter must be located filter or clean the activated carbon filter with behind the cell. DO NOT place the activated liquid, especially alcohol, gasoline, paint thinner, carbon filter in front of the cell.
  • Page 10: Important Safety Precautions

    IMPORTANT SAFETY PRECAUTIONS 125V 2A Copper Wire Do not disassemble or modify this equipment. Use a fuse with proper capacity. Never use a Unwarranted tampering can lead to fire, electric wire in place of a fuse. Doing this may lead to shock and unit malfunction.
  • Page 11: Part Names And Description

    PART NAMES AND DESCRIPTION Main Unit 211301 211201 211312 211501 211115 211110 202203 202501 202204 211111 211101 202807 211109 101201 211112 101324 211801 211102 101529 101370 101325 202109 211502 101346 101351 202915 202508 211103 101345 211317 202906 202914 202507 101348 211904 211106 101347...
  • Page 12: Part Numbers And Names

    Part Numbers and Names 211201 Plastic Top Cover 211502 Power Contact Plate 211301 Display Circuit Board 202915 Activated Carbon Filter (Complete) 211312 Gas Sensor 202906 Electronic Cell (Complete) 211501 Fan Motor Screen 202914 Pre-filter (Complete) 211110 Screen metal frame 202507 Ground Contact Plates 211115 Fan motor top plate 211106 Front Panel Unit (Air Intake Grill) 202203 Fan Housing...
  • Page 13: Before Operation

    BEFORE OPERATION Remote Control Setup Preparing the remote control The battery is already set in the remote control, pull out the clear sheet from the battery cover before using. How to use the remote control a) Point the transmitter of the remote control towards the receiver of the main unit. If an obstruction to the signal exists, the remote control will not operate.
  • Page 14: Operation

    OPERATION Display Indicator Lights SPEED Indictator Light When the power is on, the unit is set at the L speed indicator light, select the TIMER Indicator Light speed by pressing the When the TIMER SPEED button. button pressed, the indicator light will light up.
  • Page 15: Main Unit Operation

    OPERATION Main Unit Operation Connect the Power When the power plug is inserted into the wall outlet, all the indicators on the display panel will light up for 2 seconds. (As shown in the diagram below) . TIMER Button Press the TIMER button to select the time for operation.
  • Page 16: Remote Control Operation

    OPERATION Remote Control Operation POWER (ON/OFF) Button The unit will start operating when the POWER button is pressed. Pressing the button again will stop operation. Transmitter TIMER Button The set time switches every time the button is pressed as SPEED Button shown below.
  • Page 17: Care And Maintenance

    CARE AND MAINTENANCE WARNING Cleaning the unit while it is plugged in may result electric shock, electric spark and serious injury. Unplug the unit before cleaning or maintenance! To maintain optimum performance of this air purifier, please clean the unit including the pre-filter and electronic cell periodically.
  • Page 18: Cleaning The Electronic Cell

    CARE AND MAINTENANCE Cleaning the Electronic Cell Remove the electronic cell 1. Stop the operation and unplug the unit. 2. After waiting for 5-10 seconds, open the front panel. 3. Pull the cell straight up and out of the front panel. How to clean the electronic cell 1.
  • Page 19: Photo Catalytic Filter And Uv Lamp

    CARE AND MAINTENANCE Wire screen Carbon filter side side Correct Wrong Place the activated carbon filter so that the wire DO NOT place the carbon fiber side facing the screen side is facing the cell! cell or in front of the cell! It may cause fire! Photo catalytic Filter and UV Lamp 1.
  • Page 20: Troubleshooting

    TROUBLESHOOTING Service problems that appear to be major can often be solved easily. You can be your own troubleshooter by reviewing the following guide. All other servicing should be done by a Surgicall Clean Air authorized service center. Case What to Check Measure The system does not Power failure?
  • Page 21: Wiring Diagram

    WIRING DIAGRAM E-22...
  • Page 22: Service Reminder Schedule

    SERVICE REMINDER SCHEDULE Pre-filter Wash Reminder Year Memo: Electronic Cell Wash Reminder Year Memo: E-23...
  • Page 23 RespirAide Tech Inc. 13-100 Hanlan Road Woodbridge, Ontario Canada L4L 4V8 Tel: 1-866-874-2532 Fax: 1-905-850-5553 www.respiraide.com RespirAide reserves the right to revise or modify products and/or specifications without notice.The contents of this manual are subject to change without notice. 0709-1-500-211704...

Table of Contents