BEFORE OPERATING, READ ALL INSTRUCTIONS IN THIS MANUAL CAREFULLY. CONTENTS FOR CUSTOMER ASSISTANCE ........CONSUMER LIMITED WARRANTY ......HOW IT WORKS ............FEATURES AND SPECIFICATIONS ......IMPORTANT SAFETY PRECAUTIONS E-8~11 ......Warning ......................Cautions Concerning Operation PART NAMES AND DESCRIPTION ......
FOR CUSTOMER ASSISTANCE If you have questions about your air purifier, call the customer service number. Before calling, please note the model and serial number located on the back of the unit and fill in the following information below. This information will help us answer your questions much more quickly.
LIMITED WARRANTY Congratulations on your investment RespirAide Tech Inc. (hereinafter called RTI) gives you the following limited warranty for this product only if it was originally purchased from RTI or from an Authorized RTI Dealer. RTI warrants that this product is free, under normal use and maintenance, from any defects in material and workmanship.
HOW IT WORKS The air purifier functions as an air cleaner by helping to disinfect airborne microorganisms and removing particulates from the air. The centrifugal fans of the unit draw air through the front panel (Intake) on the front of the unit. Then it passes through the Pre-filter, the Electrostatic precipitator, the Activated Carbon Filter and the UV-Photo catalytic sterilization chamber.
No screws, hooks or tools are required. The electronic cell captures small particles on aluminum plates that are simply rinsed off in the sink. There are no expensive filters to replace. Specifications Model No. RespirAide 300T Power Requirement 120V, 60Hz, 0.71A Rated Power...
-Remove the power plug from the wall outlet before cleaning the unit and when not using the unit. Turn off all controls before unplugging. -If the power cord is damaged, it must be replaced by the manufacturer, its service agent, RespirAide authorized service or similarly qualified person.
Page 8
IMPORTANT SAFETY PRECAUTIONS This manual classifies precautions into WARNINGS and CAUTIONS. Be sure to follow all precautions below: They are important for ensuring your safety. WARNING CAUTION If you do not follow these instructions If you do not follow these instructions ...
Page 9
IMPORTANT SAFETY PRECAUTIONS DO NOT wash or reuse the activated carbon The activated carbon filter must be located filter or clean the activated carbon filter with behind the cell. DO NOT place the activated liquid, especially alcohol, gasoline, paint thinner, carbon filter in front of the cell.
IMPORTANT SAFETY PRECAUTIONS 125V 2A Copper Wire Do not disassemble or modify this equipment. Use a fuse with proper capacity. Never use a Unwarranted tampering can lead to fire, electric wire in place of a fuse. Doing this may lead to shock and unit malfunction.
Part Numbers and Names 211201 Plastic Top Cover 211502 Power Contact Plate 211301 Display Circuit Board 202915 Activated Carbon Filter (Complete) 211312 Gas Sensor 202906 Electronic Cell (Complete) 211501 Fan Motor Screen 202914 Pre-filter (Complete) 211110 Screen metal frame 202507 Ground Contact Plates 211115 Fan motor top plate 211106 Front Panel Unit (Air Intake Grill) 202203 Fan Housing...
BEFORE OPERATION Remote Control Setup Preparing the remote control The battery is already set in the remote control, pull out the clear sheet from the battery cover before using. How to use the remote control a) Point the transmitter of the remote control towards the receiver of the main unit. If an obstruction to the signal exists, the remote control will not operate.
OPERATION Display Indicator Lights SPEED Indictator Light When the power is on, the unit is set at the L speed indicator light, select the TIMER Indicator Light speed by pressing the When the TIMER SPEED button. button pressed, the indicator light will light up.
OPERATION Main Unit Operation Connect the Power When the power plug is inserted into the wall outlet, all the indicators on the display panel will light up for 2 seconds. (As shown in the diagram below) . TIMER Button Press the TIMER button to select the time for operation.
OPERATION Remote Control Operation POWER (ON/OFF) Button The unit will start operating when the POWER button is pressed. Pressing the button again will stop operation. Transmitter TIMER Button The set time switches every time the button is pressed as SPEED Button shown below.
CARE AND MAINTENANCE WARNING Cleaning the unit while it is plugged in may result electric shock, electric spark and serious injury. Unplug the unit before cleaning or maintenance! To maintain optimum performance of this air purifier, please clean the unit including the pre-filter and electronic cell periodically.
CARE AND MAINTENANCE Cleaning the Electronic Cell Remove the electronic cell 1. Stop the operation and unplug the unit. 2. After waiting for 5-10 seconds, open the front panel. 3. Pull the cell straight up and out of the front panel. How to clean the electronic cell 1.
CARE AND MAINTENANCE Wire screen Carbon filter side side Correct Wrong Place the activated carbon filter so that the wire DO NOT place the carbon fiber side facing the screen side is facing the cell! cell or in front of the cell! It may cause fire! Photo catalytic Filter and UV Lamp 1.
TROUBLESHOOTING Service problems that appear to be major can often be solved easily. You can be your own troubleshooter by reviewing the following guide. All other servicing should be done by a Surgicall Clean Air authorized service center. Case What to Check Measure The system does not Power failure?
SERVICE REMINDER SCHEDULE Pre-filter Wash Reminder Year Memo: Electronic Cell Wash Reminder Year Memo: E-23...
Page 23
RespirAide Tech Inc. 13-100 Hanlan Road Woodbridge, Ontario Canada L4L 4V8 Tel: 1-866-874-2532 Fax: 1-905-850-5553 www.respiraide.com RespirAide reserves the right to revise or modify products and/or specifications without notice.The contents of this manual are subject to change without notice. 0709-1-500-211704...