Adjusting Presser Foot Height and Alignment

The distance between the bottom of the presser foot in up position and the needle plate
should be 6.0 mm.
<TO ADJUST>
1 Remove the face plate (see page 1) and needle.
2 Lower the feed dog below the needle plate. Place a block 6 mm thick under the presser foot
and lower
the presser foot lifter.
3 Loosen the setscrew (A). Raise the presser foot lifter and tighten the setscrew (A) firmly.
4 Attach the needle and face plate.
NOTE:
Make sure that the presser foot should be parallel to the feed dog slots (B) in the needle plate.
Presser foot height
Presser foot
Needle plate
Setscrew A
6 mm
Feed dog
Presser foot lifter
Presser foot alignment
6
Presser foot should
be parallel to the feed
dog slots.