When using the humidifier under normal
conditions the Cartridge (6) should be
replaced every 30 – 40 fillings. Replace
more often in hard water areas.
3.
Replacement ACA-817E Cartridges (6) are
available where you purchased your
humidifier.
4.
Do not operate the humidifier without the
Demineralization Cartridge (6) and do not
use an exhausted cartridge. In areas, where
water has a high hardness, there might be
an output of minerals, noticeable as "white
dust" (see extra filters).
EXTRA FILTERS
In hard water areas, there might be an output of
minerals, noticeable as "white dust". In order to
determine the hardness of the water you may ask
your water company.
KF-520E K-Filter
1.
If the hardness of the water is extremely
high the cold tap water should be filtered
with the KF-520E K-Filter before filling it into
the Water Tank (6).
2.
The KF-520E K-Filter reduces the calcium
carbonate content of the water.
3.
The KF-520E K-Filter can be regenerated
and therefore has a long lifetime.
4.
Using the KF-520E K-Filter please carefully
read and follow the special instructions
included in each filter package.
SF-530E A-Filter
1.
The SF-530E A-Filter should be used when
salt is added to the water by use of a water
softening plant. If the water has an
extremely high salt content the cold tap
water should first be filtered with the
SF-530E filter.
2.
Then filter the water with the KF-520E
K-Filter. The water, filtered twice, can now
be filled into the Water Tank (6).
3.
The SF-530E A-Filter can be regenerated
and therefore has a long lifetime.
4.
Using the SF-530E please carefully read
and follow the special instructions included
in each filter package.
ENGLISH
FILLING THE WATER TANK
1.
Check that the Power Switch (12) is in the
Off position and that the plug and not
plugged in.
2.
Remove the Directional Mist Nozzle (1)
from the Water Tank (3).
3.
Remove the Water Tank (3) from the Base
(7) and turn it upside down. Open the Tank
Cap (4) by turning it counter-clockwise.
4.
Fill the Water Tank (3) only with clean, cool
tap water (approx. 6 litres). Do not use
warm or hot water. This can damage the
Cartridge (6) and the Ultrasonic Nebulizer
(10) and void the warranty.
5.
Do not add any substances into the Water
Tank (3) or Reservoir (7) or onto the
Cartridge (6) (e.g. inhalant, aromatic
substances etc.). This can cause health
hazards.
6.
Close the Water Tank (3) with the Tank Cap
(4) by turning it clockwise.
7.
Check that the Cartridge (6) is in place.
8.
Turn the Water Tank (3) upright. Make sure
that the Tank Cap (4) is in place and check
it for leaks.
9.
Replace the filled Water Tank (3) on the
Base (11) and the Directional Mist Nozzle
(1) into the Water Tank (3). Wait for
approx. 15 minutes before operating the
humidifier, so that the water can run
through the Cartridge (6) into the Reservoir (7).
OPERATING INSTRUCTIONS
1.
Check that the Water Tank (3) is filled and
that the Cartridge (6) is in place.
2.
Check that the Power Switch (12) is in the
Off-position. Plug the supply cord into the
outlet. Do not touch the supply cord with
wet hands.
3.
Turn the Power Switch (12) to the desired
position. The Pilot Light (13) illuminates.
Turn the Power Switch (12) clockwise to
increase mist output; turn it counter-
clockwise to decrease mist output.
4.
Direct the Mist Nozzle (1) away from
people, objects or walls.
5.
If surplus humidity condenses on furniture,
walls or floors in closed or small rooms, turn
the Power Switch (12) counter-clockwise to
decrease mist output and open the door to
the room. If this does not solve the problem
turn the Power Switch (12) to the
Off-position and unplug the humidifier.