Removing The Thermal Fuse & Outlet Thermistor (Electric) - Whirlpool WED9500E SERIES Service Manual

9.2 cu. ft. steam dryer
Table of Contents

Advertisement

Removing the Thermal Fuse & Outlet Thermistor
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or
electrical shock.
To Remove the Thermal Fuse & Outlet Thermistor
1. Unplug dryer or disconnect power.
2. Perform the procedures on page 4-4, "Removing the
Top Panel" and "Removing the Console/UI" prior to
performing the following steps.
3. Perform the procedures on page 4-6, "Removing the Front
Panel" prior to performing the following steps.
4. Remove the four (4) 1/4" hex-head screws from the lint
duct as illustrated in Figure 1. Swivel the lint duct down
and remove.
Swivel down and
remove lint duct.
Figure 1
5. Disconnect the two wire connectors from the thermal
fuse or outlet thermistor terminals (see Figure 2).
6. Remove the screw(s) from the thermal fuse or outlet
thermistor and remove the component from the blower
housing (see Figure 2).
Blower Housing
Thermal Fuse
2 Lt Blue Wires,
1 Screw
Outlet Thermistor
2 Red Wires,
2 Screws
Whirlpool & Maytag 9.2 Cu. Ft. Steam Dryer
COMPONENT ACCESS
Figure 2
4-11
n

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Medb955f seriesMgdb955f seriesWgd9500e series

Table of Contents