[V.COM R]
• Make this adjustment through a visual check.
Note: The view angle correction must be turned off.
Before this adjustment, the Contrast Adjustment must be finished.
Condition:
Input signal
Monoscope signal
Measurement point
Right LCD screen
Measuring equipment
Visual check
Adjustment page
D
Adjustment address
28
Adjustment Procedure:
(1) Select EXT. VIDEO AUDIO mode, and picture and tone qual-
ity standard setting. (See page 22)
(2) View angle correction OFF: Connect CN404 pin 2 (EAC OFF)
and pin 1 (GND) on the RG-46P board.
(3) Set (or confirm) data:01 to page: 1, address: 00.
(Cancel D page protect)
(4) On page: D, address: 28, change data with the PLAY and STOP
buttons and press the PAUSE button to write data so that hori-
zontal streaks do not wobble on the display when looking into
the right finder window.
Adjustment and Adjustment Parts: RG-46P board (see page 33)
[V.COM L]
• Make this adjustment through a visual check.
Note: The view angle correction must be turned off.
Before this adjustment, the Contrast Adjustment must be finished.
Condition:
Input signal
Monoscope signal
Measurement point
Left LCD screen
Measuring equipment
Visual check
Adjustment page
D
Adjustment address
29
Adjustment Procedure:
(1) Select EXT. VIDEO AUDIO mode, and picture and tone qual-
ity standard setting. (See page 22)
(2) View angle correction ON: Connect CN404 pin 2 (EAC OFF)
and pin 1 (GND) on the RG-46P board.
(3) Set (or confirm) data: 01 to page: 1, address: 00.
(Cancel D page protect)
(4) On page: D, address: 29, change data with the PLAY and STOP
buttons and press the PAUSE button to write data so that hori-
zontal streaks do not wobble on the display when looking into
the left finder window.
Adjustment and Adjustment Parts: RG-46P board (see page 33)
Page 31