Setting Up PMS Integration
Stop
No
Yes
Basic PMS Setup
Start
Do you want to
connect your phone
system to a third-
party PMS system?
In 2801, for Modem No. enter 1.
For DCI No. , enter the software
port number of the DCI connected
to the PMS system.
Is the DCI port used
for PMS set up in
programming?
No`
In 1201 register 65, set
parameters to match
settings of connected PMS.
In 1202, assign port type
and subtype for DCI port
used for PMS.
!! Initialize DCI port
used for PMS !!
Use program 1206 or
Service Code 880.
Stop
PMS Integration
Make sure your
Yes
system has an LAPB
PCB installed.
In 2802, be sure the PMS system
is assigned to the same Tenant
Group as the Hotel mode
telephones.
In 1201 register 66, set
RTS to disabled (1), DTR
and CD to on (0) and
disable flow control (0).
In 1203, be sure PMS DCI and
Hotel mode telephones are in
same Tenant Group.
2-17