Issue 10/06
2.3.1
Installing communication options and/or pulse encoder
evaluation module
Frame Size C
NOTE
When installing the following options – PROFIBUS module, DeviceNet module,
CANopen option module and/or pulses encoder evaluation module, the mounting
depth of the drive inverter is increased!
Please refer to the relevant Operating Instructions for the actual procedure.
Frame Sizes FX and GX
The front cover of the MICROMASTER 440 is designed so that the control module
(normally the SDP) is almost flush with the opening in the front cover.
If more than one option is to be installed in the electronic box, it is necessary to
position the entire electronic box further to the rear.
Installing the options
Remove the front cover:
• Unscrew two screws at the bottom side of the front cover.
• Lift front cover up and out.
Remove retaining screws on the electronic box.
Screw on electronic box in correct installation position as shown in Figure 2-7
Install additional options.
Reinstall front cover.
Figure 2-7
Installation of options for the electronic box