3
Parameters operating area
3.3 R parameters
3.3
R parameters
3-34
Further buttons
Abort (softkey)
Recall
creating a cutting edge or new tool
Function
R parameters can be displayed and modified.
Prerequisites
• The R Parameters softkey has been pressed in the Parameters
Operating Area working window.
The following working window is then displayed:
R parameters working window
Operating sequence
• Select the R parameters with the cursor.
• Use the numerical input to modify the values.
• Press Input to accept the value (or exit the field to do this).
Further buttons
Delete all
Sets all R parameters to 0.000 (after a safety prompt)
Search
R Parameter Search working window: Search for a
desired R parameter by inputting its number
SINUMERIK 840D/840Di/810D Operator's Guide Handheld Terminal 6 (BAH) - 03.04 Edition
Cancel input or
Return to the starting window without
Siemens AG, 2004. All rights reserved.
3
03.04