1.4 OPTIONAL EXTRA KITS

Horizontal Flue Terminal 600mm long
Horizontal Telescopic Flue 600mm long
Horizontal Telescopic Flue 1000mm long
Flue Extension Ducts (1000mm long)
Flue Extension Ducts (2000mm long)
Flue Extension Ducts (500mm long)
30-up to 8m
35-up to 6m
90
Elbow Kit (maximum per installation).
o
30-upto 6 elbows
35-upto 4 elbows
45
Elbow Kit (maximum per installation).
o
30-upto 6 elbows
35-upto 4 elbows
Concentric Flue Screw Retaining Kit
Roof Flue Kit inc. vertical connection (to a max. of 7.5m)
Powered Vertical Flue Kit (5m primary and 17m secondary
is a typical maximum length. For alternative details refer to
Powered Vertical Instructions)
Weather Collar (Universal)
Weather Collar (Flat Roof)
High Level Flue Outlet Kit
Flue Deflector Kit
Balcony Flue Kit
Soffit Flue Kit
Raised Horizontal Flue Outlet Kit
Adjustable Flue Support Bracket
Mechanical Timer (24 hr) 5V Kit
Stand-Off Kit
DHW Expansion Vessel Kit
Condensate Pump Kit
Security Bracket Kit
Safety Valve Drain Outlet Pipe Kit
OpenTherm Harness Kit
Installation and Servicing
SECTION 1 - GENERAL

1.5 SAFETY

Current Gas Safety (installation and use) regulations or rules
in force:
The appliance is suitable only for installation in GB and IE and
should be installed in accordance with the rules in force.
In GB, the installation must be carried out by a Gas Safe
Registered Engineer. It must be carried out in accordance with
the relevant requirements of the:
Gas Safety (Installation and Use) Regulations
Appropriate Building Regulations, either The Building
Regulations, The Building Regulations (Scotland), Building
Regulations (Northern Ireland).
Water Fittings Regulations or Water byelaws in Scotland.
Current I.E.E. Wiring Regulations.
Where no specific instructions are given, reference should be
made to the relevant British Standard Code of Practice.
In IE, the installation must be carried out by a Registered Gas
Installer (RGII) and installed in accordance with the current edition
of I.S.813 "Domestic Gas Installations", the current Building
Regulations and reference should be made to the current ETCI
rules for electrical installation.
Detailed recommendations are contained in the following British
Standard Codes of Practice:
BS.5440:1
BS.5440:2
BSEN. 12828 Heating Systems in buildings: Design for water
BSEN 12831
BSEN 14336
BS.5546
BS.6798
BS.6891 Low pressure installation pipes.
Health & Safety Document No. 635.
The Electricity at Work Regulations, 1989.
The manufacturer's notes must NOT be taken, in any way, as
overriding statutory obligations.
IMPORTANT. These appliances are CE certificated for safety
and performance. It is, therefore, important that no external
control devices, e.g. flue dampers, economisers etc., are
directly connected to these appliances unless covered by
these Installation and Servicing Instructions or as otherwise
recommended by the manufacturer in writing. If in doubt please
enquire.
Any direct connection of a control device not approved by the
manufacturer could invalidate the certification and the normal
appliance warranty. It could also infringe the Gas Safety
Regulations and the above regulations.

1.6 SAFE HANDLING OF SUBSTANCES

No asbestos, mercury or CFCs are included in any part of the
boiler or its manufacture.
Flues (for gas appliances of rated input not
exceeding 70 kW).
Ventilation (for gas appliances of rated input not
exceeding 70 kW).
based heating systems.
Heating Systems in buildings: Method for
calculation of the design heat load.
Heating Systems in buildings: Installation and
commissioning of water based heating
systems.
Installation of gas hot water supplies for domestic
purposes (2nd Family Gases)
Installation of gas fired hot water boilers of rated
input not exceeding 70 kW.
11