Service manual Master S 400 and 500
Resetting the calibration data to factory values:
Rotate potentiometer until "FAC" appears in the display and select it with short press of "A/V"
button, display shows "OFF".
Change value with potentiometer to "rES" and when exiting the calibration state by long pressing
A/V button, calibration data will be reset.
See practical calibration instructions later on this manual.
13
Kemppi Oy
Version 1.1
5.9.2014