Configuring for initiator mode
To configure the N3700 storage system for initiator mode, complete the following
steps.
1. Remove the FCP license by entering the following command:
2. Reboot the system by entering the following command:
3. After the reboot, verify that port C is in initiator mode by entering the following
4. Enable port C by entering the following command.
For more information about configuring your SAN, see the IBM System Storage N
series Data ONTAP Block Access Management Guide for your version of Data
ONTAP.
18
IBM System Storage N series: N3700 Hardware and Service Guide
license delete fcp
Example:
n3700a> license delete fcp
Fri Dec 5 14:59:02 EST [n3700a: fcp.service.shutdown:info]: FCP service
shutdown
cf.takeover.on_panic is changed to off
A reboot is required for TapeSAN service to become available.
unlicensed fcp.
FCP disabled.
n3700a> Fri Dec 5 14:59:02 EST [n3700a: rc:notice]: fcp unlicensed
reboot
command:
sysconfig
Example:
n3700a> sysconfig
NetApp Release xxx: Mon Aug 25 02:20:04 PDT 2003
System ID: 0084165669 (n3700a); partner ID: 0084165671 (n3700b)
System Serial Number: 379589 (n3700a)
slot 0: System Board
Processors:
Processor revision: B2
Processor type:
Memory Size:
slot 0: FC Host Adapter 0b
14 Disks:
1 shelf with EFH
slot 0: FC Host Adapter 0c
slot 0: SB1250-Gigabit Dual Ethernet Controller
e0a MAC Address: 00:a0:98:00:d5:90 (100tx-fd-up)
e0b MAC Address: 00:a0:98:00:d5:91 (auto-unknown-cfg_down)
slot 0: NetApp ATA/IDE Adapter 0a (0x00000000000001f0)
0a.0
Note: In the above example, Fibre Channel port C is identified as FC Host
Adapter 0c.
storage enable adapter 0c
Example:
n3700a> storage enable adapter 0c
Mon Dec 8 08:55:09 GMT [rc:notice]: Onlining Fibre Channel adapter 0c.
host adapter 0c enable succeeded
2
1250
1022 MB
952.0GB
122MB