Panasonic KX-NS1000 Pc Programming Manual page 221

Pure ip-pbx
Hide thumbs Also See for KX-NS1000:
Table of Contents

Advertisement

Control Condition of Remote SIP-MLT—PERIODIC Ability
Specifies whether alive monitoring is performed for connected remote extensions.
Value Range
Enable, Disable
Maintenance Console Location
9.5 PBX Configuration—[1-1] Configuration—Slot—Site Property
Feature Guide References
5.2.2.3 Simple Remote Connection
Control Condition of Remote SIP-MLT—PERIODIC Packet Sending Interval Time
(s)
Specifies the polling interval for alive monitoring when PERIODIC Ability is set to "Enable".
Value Range
30–3600 s
Maintenance Console Location
9.5 PBX Configuration—[1-1] Configuration—Slot—Site Property
Feature Guide References
5.2.2.3 Simple Remote Connection
Echo Cancellation
The settings in this tab are for non-IP calls.
Echo Canceller Ability
Specifies the echo canceller ability time.
Value Range
OFF, 64 ms, 128 ms
Maintenance Console Location
9.5 PBX Configuration—[1-1] Configuration—Slot—Site Property
DSP Digital Gain (Down)
Specifies the DSP Digital Gain for the down voice path.
Value Range
-14–6 dB
9.5.1 PBX Configuration—[1-1] Configuration—Slot—Site Property—Main
PC Programming Manual
221

Hide quick links:

Advertisement

Table of Contents
loading