3. Specifications
3.1 General Specifications
Item
Operating ambient temperature
0 to 40C
Storage ambient temperature
-20 to 60C
Operating ambient humidity
10 to 90% RH, non-condensing (The wet bulb temperature is 39C or less.)
Storage ambient humidity
10 to 90% RH, non-condensing (The wet bulb temperature is 39C or less.)
Conforms to JIS
Vibration resistance
B3502 and
IEC61131-2
Shock resistance
Conforms to JIS B3502, IEC 61131-2 (147 m/s
Must be free of lamp black, corrosive gas, flammable gas, or excessive amount of electroconductive dust particles and
Operating atmosphere
must be no direct sunlight. (Same as for saving)
*1
2000 m (6562 ft) max.
Operating altitude
Overvoltage category
*2
 or less
Pollution degree
*3
2 or less
Cooling method
Self-cooling
*1 Do not use or store the GOT under pressure higher than the atmospheric pressure of altitude 0m (0ft.). Failure to observe this instruction may cause a malfunction.
When the air inside the control panel is purged by pressurization, the surface sheet may be lifted by high pressure. As a result, the touch panel may be difficult to press,
and the sheet may be peeled off.
*2 This indicates the section of the power supply to which the equipment is assumed to be connected between the public electrical power distribution network and the
machinery within the premises. Category  applies to equipment for which electrical power is supplied from fixed facilities. The surge voltage withstand level for up to the
raged voltage of 300 V is 2500 V.
*3 This index indicates the degree to which conductive material is generated in the environment where the equipment is used.
In pollution degree 2, only non-conductive pollution occurs but temporary conductivity may be produced due to condensation.
3.2 Performance Specifications
Item
Type
TFT color liquid crystal display (High intensity and wide angle view)
Screen size
6.5"
640  480 dots
Resolution
W132.5 (5.22)  H99.4 (3.91) [mm] (inch)
Display size
16-dot standard font: 80 characters  30 lines, 12-dot standard font: 106 characters  40 lines
Display character
Display
*1
section
Display color
65536 colors
Left/Right: 80 degrees, Top: 60 degrees, Bottom: 80 degrees (Horizontal format)
Display angle
*2
2
Intensity of LCD only
550[cd/m
]
Intensity adjustment
8-level adjustment
Life
Approx. 41,000h. (Operating ambient temperature: 25C)
LED type
Backlight
Backlight off/screen saving time can be set.
Type
Analog resistive film
Minimum 2  2 dots (per key)
Key size
To u c h
N u m b e r o f p o i n t s t o u c h e d
panel
*4
Simultaneous presses not allowed. (Only 1 point can be touched.)
simultaneously
Life
1 million times or more (operating force 0.98N max.)
Flash memory (Internal), for storing project data (15Mbytes) and OS
Memory
*5
C drive
Life (Number of write times): 100,000 times
Buzzer output
Single tone (tone length adjustable)
Operation switch
6 switches (6 contacts/common), N/O contact, Maximum rating 10mA/24VDC, Life: 1,000,000 times
1 switch (single wiring) (IDEC HE3B-M2PB), Enable switch (deadman switch) 3-position system of OFF
Grip switch
2 N/O contacts, Maximum rating 1A/24VDC (resistance load), Maximum rating 0.3A/24VDC (induction load), Life: 100,000
times
1 switch (single wiring) (IDEC XA1E-BV303R)
Switch
Emergency stop switch
2 N/C contacts, Maximum rating 1A/24VDC (resistance load), Maximum rating 0.3A/24VDC (induction load), Life: 100,000
times
1 switch (single wiring) (IDEC AS6M-2KT1PB)
Keylock switch
2-notch type (Manual stop at each position/A key can be inserted and removed on only the left side./On the right side, a key
(2-position switch)
cannot be removed./Two keys are provided.)
2-position, Maximum rating 1A/24VDC (resistance load), Maximum rating 0.3A/24VDC (induction load), Life: 100,000 times
Environmental protective structure
*6
IP65F (valid when the external cable is connected, except for the connector conversion box side)
3.3 Power Supply Specifications
Item
Input power supply voltage
24V DC (+10% -15%)
Power consumption
11.6W (480mA/24V DC) or less
At backlight off
8.2W (340mA/24V DC) or less
Inrush current
30A or less (maximum load) 2ms
*1
Within 5ms
Permissible instantaneous power failure time
Noise immunity
Noise voltage: 1000Vp-p, Noise width: 1s (by noise simulator of 30 to 100Hz noise frequency)
Dielectric withstand voltage
500V DC for 1 minute (across power supply terminals and earth)
Insulation resistance
10M or larger by insulation resistance tester (across power supply terminals and earth)
*1 The GOT continues to operate even upon 5ms or shorter instantaneous power failure.
The GOT stops operating if there is extended power failure or voltage drop, while it automatically resumes operation as soon as the power is restored.
3.4 External Dimensions
201 (7.92")
4. Maintenance and Inspection
The GOT does not include consumable components that will cause the shorten life.
However, note that battery life is 5 years and LCD life is 50,000 hours.
It is recommended to replace the battery periodically. (For the replacement of the
liquid crystal screen, please consult your nearest sales office or FA Center.)
4.1 Daily Inspection
Daily inspection items
Inspection
No.
Inspection Item
Criterion
Method
R e p l a c e
1
Loose connectors
Visual check
Not loose
external cable.
Dirt on protection
Not
Replace with
Visual check
sheet
outstanding
new one
2
Foreign material
No foreign
Visual check
Remove clean
attachment
matter sticking
Refer to the following for the model names of the protection sheet or the
replacement procedure.
GT16 Handy GOT User's Manual
Specifications
Frequency
Acceleration
Half-amplitude
5 to 9Hz
--
3.5mm
Under intermittent
vibration
9 to 150Hz
9.8m/s
2
5 to 9Hz
--
1.75mm
Under continuous
vibration
9 to 150Hz
4.9m/s
2
2
, 3 times each in X, Y and Z directions)
Specifications
GT1665HS-VTBD
*3
Specifications
GT1665HS-VTBD
21 (0.83") 50 (1.97") 47 (1.86")
Unit: mm (inch)
4.2 Periodic Inspection
Yearly or half-yearly inspection items
The following inspection should also be performed when equipment has been
moved or modified or the wiring changed.
Inspection
No.
Inspection Item
Method
Ambient
Make
0 to 40C
temperature
measurement
with
Action
Surrounding
Ambient
1
thermometer
10 to 90%RH
environment
humidity
or hygrometer
Measure
No corrosive
Atmosphere
corrosive gas
gas
24V DC
Power supply voltage
Measure
20.4 to 26.4V
2
check
voltage across
DC
terminals.
Mounting
Dirt, foreign
No dirt, foreign
3
Visual check
status
matter
matter sticking
Connection
L o o s e
4
Visual check
Not loose
status
connectors
Check the
system alarm
(error code:
( P r e v e n t i v e
5
Battery
500) report on
maintenance)
the Alarm
Information
screen
Item
External dimensions
Weight
Compatible software package
POWER LED
LED
Sweep Count
LED for operation switch display 6 LEDs, green (lighting control from the display section)
LED for grip switch display
--
10 times each in X,
Y and Z directions
Built-in clock precision
Type
--
Battery
Backup target
Life
RS-422/485
RS-232
Ethernet
Built-in
interface
USB
CF card
*1 Bright dots (always lit) and dark dots (unlit) may appear on a liquid crystal display panel. It is impossible to completely avoid this symptom, as the liquid crystal display
comprises of a great number of display elements. Flickers may be observed depending on the display color.
Please note that these dots appear due to its characteristic and are not caused by product defect.
Flickers and partial discoloration may be generated on the liquid crystal display panel due to the display contents or the contrast adjustment. However, please note that
these phenomena appear due to its characteristic and are not caused by product defect.
There is a difference in the display brightness and the color tones between liquid crystal display panels. When using multiple liquid crystal display panels, please note
that there is an individual difference between them.
A crosstalk (shadow as an extension of the display) may appear on the liquid crystal display panel. Please note that it appears due to its characteristic.
When the display section is seen from the outside of the display angle, the display color seems like it has changed. Please note that it is due to its characteristic.
Please note that the response time, brightness and color of the liquid crystal display panel may vary depending on the usage environmental temperature.
When the same screen is displayed for a long time, an incidental color or partial discoloration is generated on the screen due to heat damage, and it may not disappear.
To prevent heat damage, the screen saver function is effective.
For details on the screen saver function, refer to the following.
 GT16 Handy GOT User's Manual
*2 Gradation inversion is a characteristic of liquid crystal displays. Please be forewarned that depending on the displayed color, the visualization may be difficult even within
the described view angle.
*3 The GOT screen saving/backlight off function prevents images from becoming permanently etched on the display screen.
 GT16 Handy GOT User's Manual
*4 The touch panel is analog resistive film-type. If you touch the panel simultaneously in 2 points or more, the switch that is located around the center of the touched point,
if any, may operate. Do not touch the panel in 2 points or more simultaneously.
*5 ROM in which new data can be written without deleting the written data.
*6 Note that this does not guarantee all user's operation environment. The protection is not applied when the interface environment protection cover or environment
protection back cover is removed. In addition, the product may not be used in environments under exposition of oil or chemicals for a long period of time, or in
environments filled with oil-mist.
*7 If the operating ambient temperature is other than 25C, the error may become large.
ON
OFF
4.3 Battery Replacement
The battery backs up clock data, alarm history and recipe data.
Screen data is stored in the flash memory and data is retained even if the battery is
dead.
 Battery model name
Handy GOT is shipped with the following battery.
Use it at replacement.
Product name
Battery
 Battery replacement procedure
1) After keeping the GOT turned ON more than 10 minutes, turn OFF the GOT. After
turning OFF the GOT, perform the procedure 2) to 7) within 5 minutes.
2) Loosen the environmental protection back cover screws at two points on GOT
rear face to remove the cover.
3) Remove the old battery from the holder and disconnect the connecter.
4) Insert the connector of the new battery.
5) Install the battery to the GOT.
Lead (Black)
Battery
Circuit
board
Lead (Red)
6) Attach the environmental protection back cover and tighten the screws.
Tightening torque: 0.36 to 0.48 N•m
7) Turn the GOT power on.
8) Check if the battery condition is normal with the utility.
Criterion
Action
Refer to the following for the details of battery status display.
For use in control
panel,
temperature
inside control
panel is ambient
temperature
Change supply
power
 Battery life
Approximate battery life:
Remove, clean
5 years (ambient temperature: 25C)
Battery replacement: In 4 to 5 years
Replace external
Approximate life is 5 years, but life may be shorter depending on the ambient
cable.
temperature, therefore, note that the battery must be replaced in 4 to 5 years. Make
Replace with new
sure to purchase a new battery as needed as it self-discharges.
battery when the
current battery
Battery status can be confirmed on a GOT utility screen.
has reached the
For details of battery status or how to output alarm, refer to the following:
specified life
span, even if
battery voltage is
not displayed.
Specifications
GT1665HS-VTBD
W201 (7.91)  H230 (9.06)  D97 (3.82) [mm] (inch)
Approx.1.2kg (GT16 Handy GOT main unit only)
GT Designer3 Version1.14Q or later
1 LED
Lit in green: Power is correctly supplied.
Lit in orange: Screen saving and backlight not lit.
Blinks in orange/green: Blown back light bulb.
Not lit: Power is not supplied.
1 LED, green (lighting control from display unit part)
3.47 to 8.38 sec/day (Operating ambient temperature of 25C)
Magnesium maganese dioxide lithium primary battery
Clock data and maintenance time notification data, system log data
Approx. 5 years (Operating ambient temperature of 25C)
RS-422/485, RS-232 1ch each
Transmission speed : 115,200/57,600/38,400/19,200/9,600/4,800bps
Connector shape
: Square 42 pins (male)
Application
: PLC communication (Select either RS-422/485 or RS-232 when used)
Data transfer method: 100BASE-TX, 10BASE-T 1ch
Connector shape
: Square 42 pins (male)
Application
: For PLC communication, Gateway functions, PC communication (Project data upload/download,
OS installation)
USB (Full Speed 12Mbps) Host 1ch
Connector shape
: TYPE-A
Application
: Data transfer, data storage
USB (Full Speed 12Mbps) Device 1ch
Connector shape
: Mini-B
Application
: PC communication (Project data upload/download, OS installation, FA transparent function)
Compact flash slot 1ch
Connector shape
: Dedicated for TYPE I
Application
: Data transfer, data storage, GOT startup
5. Precautions
5.1 Cautions on Using Emergency Stop Switch
1) When using the emergency stop switch in the handy GOT, judge the validity to
use the emergency stop switch in accordance with the risk assessment in your
system.
2) When using the parallel circuit (which disables the emergency stop status while
the handy GOT is removed), the system may not conform to the safety
standards. Check the safety standards required in the system, and then judge
Model name
the validity to use the emergency stop switch.
GT15-BAT
「电器电子产品有害物质限制使用标识要求」 的表示方式
Note: This symbol mark is for China only.
含有有害6物质的名称, 含有量, 含有部品
 本产品中所含有的有害 6 物质的名称, 含有量, 含有部品如下表
所示。
Environmental
protection
back cover
screw
部件名称
外壳
Connector for
印刷基板
battery connection
显示器
背光灯
GOT
Battery
(CCFL)
电缆
本表格依据SJ/T 11364的规定编制。
○:表示该有害物质在该部件所有均质材料中的含量均在GB/T
26572规定的限量要求以下。
×:表示该有害物质至少在该部件的某一均质材料中的含量超出GB/
Insert the red lead as
T 26572规定的限量要求。
to pass it through the
notch on the circuit board.
Insertion
direction
This manual confers no industrial property rights or any rights of any other
kind, nor does it confer any patent licenses. Mitsubishi Electric Corporation
cannot be held responsible for any problems involving industrial property rights
which may occur as a result of using the contents noted in this manual.
Warranty
Exclusion of loss in opportunity and secondary loss from warranty liability
Regardless of the gratis warranty term, Mitsubishi shall not be liable for
compensation to:
GT16 Handy GOT User's Manual
(1) Damages caused by any cause found not to be the responsibility of
Mitsubishi.
(2) Loss in opportunity, lost profits incurred to the user by Failures of Mitsubishi
products.
(3) Special damages and secondary damages whether foreseeable or not,
Environmental
compensation for accidents, and compensation for damages to products
protection
other than Mitsubishi products.
back cover
(4) Replacement by the user, maintenance of on-site equipment, start-up test run
screw
and other tasks.
This product has been manufactured as a general-purpose part for general
industries, and has not been designed or manufactured to be incorporated in
a device or system used in purposes related to human life.
Before using the product for special purposes such as nuclear power, electric
power, aerospace, medicine or passenger movement vehicles, consult with
Mitsubishi Electric.
This product has been manufactured under strict quality control. However
when installing the product where major accidents or losses could occur if the
product fails, install appropriate backup or failsafe functions in the system.
GT16 Handy GOT User's Manual
HEAD OFFICE : TOKYO BUILDING, 2-7-3 MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN
*7
产品中有害物质的名称及含量
有害物质
多溴
六价铬
多溴联苯
二苯醚
(Pb)
(Hg)
(Cd)
(Cr(VI))
(PBB)
(PBDE)
×
×
×
For safe use

Advertisement

Table of Contents

   Related Manuals for Mitsubishi Electric GT1665HS-VTBD

Comments to this Manuals

Symbols: 0
Latest comments: