Options; Program; Period Program - Danfoss CF-RC Instruction

Hide thumbs Also See for CF-RC:
Table of Contents

Advertisement

Instruction

5.1.2 Options

Menu  Rooms  Options: From the Rooms menu, select Options to get access to the
following room options:
• Set temperature: Set and lock set temperature for the room thermostat. Locking pre-
vents adjustment of set temperature on the room thermostat.
• Set Min/Max: Set and lock minimum and maximum temperatures for the room thermo-
stat. Locking prevents adjustment beyond these limits on the room thermostat.
• Change room name: Change room names by means of a list of possible room names or
you can use the Spell..... menu to key in other names.
• Set floor Min/Max: Set and lock minimum and maximum floor surface temperatures
(option only available with the CF-RF Room Thermostat with infrared floor sensor).
• Setback: Override the next or ongoing setback period (option only available if setback
program is activated, see chapter 5.2.2).
• Cooling: Disable cooling function for the room (option only available when Master Con-
troller is in cooling mode).
• Heating/cooling  Set mode: Select heating/ cooling mode to Auto, Heating or Cool-
ing (option only available when 3- or 4-pipe heating/cooling is enabled).
• Heating/cooling  Setting locked: Select heating/cooling mode to be Locked or Un-
locked (option only available when 3- or 4-pipe heating/cooling is enabled).

5.2 Program

Menu  Program: From the start-up screen, activate the Program menu to view time
programming options.
5.2.1 Period program
Menu  Program  Period program  Create program: From the Program menu, select
Period program  Create program to set room temperature for all room thermostats dur-
ing e.g. a holiday. Use the up/down and left/right selectors (fig. 1-/) to set start date,
end date and temperature for the program.Confirm each setting with OK. The created
program is diplayed. Press Yes to activate the program.
© Danfoss 03/2011
CF-RC Remote Controller
Create program
Start date : 23. Dec
End date : 1. Jan
Temperature : 15.0°C
Activate?
Yes
VIUHM602
No
Danfoss Heating Solutions
7

Advertisement

Table of Contents
loading

This manual is also suitable for:

088u0221