Reference
Scanner Diagnostics (continued)

Stitch Alignment

Selecting the Stitch Alignment item on the SCANNER DIAGNOSTICS
screen displays the STITCH ALIGNMENT screen. This is a protected
function; the diagnostic password must be entered for access. If you observe
that stitch alignment is required, call for service. The following discussion is
designed to help the user determine if stitch alignment is required.
STITCH ALIGNMENT
LEFT TO RIGHT
FRONT TO BACK
The Scanner contains three cameras, each of which captures 1/3 of the full
width of the 36-in. (91.4 mm) scanner image. The view of the left and right
cameras must be adjusted to align with the view of the center camera. The
adjustment must be correct both for left to right alignment, and front to back
alignment.
Camera 1
Camera 2
Camera 3
Stitch adjustment – Front to back
The illustration below shows the effect of misalignment of the front to back
stitch adjustment of the three cameras. If the alignment is not correct, a
mechanical adjustment must be made. This is a protected function; the
diagnostic password must be entered for access. If you observe that stitch
alignment is required, call for service.
Camera 1
Camera 2
image
image
Correct
Stitch area of
copy
Camera 1
Camera 2
image
image
Not Correct
8825/8830 DDS User Guide/81