VidSwitchPassword is the administrator password (adminpw) of the switcher
(only used for TvOneCorioMatrix).
<VideoSwitchers Model="TvOne">
<VideoSwitcher>
<VidSwitchPort>10001</VidSwitchPort>
<VidSwitchIPaddress>192.168.0.80</VidSwitchIPaddress>
<VidSwitchUserName></VidSwitchUserName>
<VidSwitchPassword></VidSwitchPassword>
</VideoSwitcher>
</VideoSwitchers>
If there is a presentation source, e.g. RGB, enter the presentation source input between
<VideoSwitchInput>, as shown in the following example. Do not remove
<PresentationConfig> if there is no presentation source.
–
TvOne supports two presentation inputs: RGB, and DVI. None can also be entered.
RGB: Presentation is taken from the VGA port.
DVI: Presentation is taken from the DVI port.
None: No presentation (the video switcher will not switch to the presentation source
during presentation mode but will continue to display the camera image instead).
–
Kramer does not have a VGA or DVI input, so None should be entered when a Kramer
MV-6 is used.
–
TvOneCorioMatrix supports None or a specified input such as: Slot_<X>_in_<Y>.
For example: Slot_5_in_1 (for input 1 of the SDI input card which is inserted in slot
5).
<PresentationConfig>
<PresentationSources>
<VideoSwitchInput>RGB</VideoSwitchInput>
</PresentationSources>
</PresentationConfig>
The system will detect the available cameras, and add the details to the config file, as
shown in the following example:
–
<CameraId>, <CameraName> and <CameraState> are read only values that are
generated by the system. Do not modify these values!
–
<CameraState> lists:
True: When there is an Active speaker and Presentation is InActive.
False: No: Active speaker and Presentation is Active.
–
<VideoSwitchInput> contains the input on which the camera is located:
1 to X (numeric) for the TvOne and Kramer model.
Slot_<X>_in_<Y> for the TvOneCorioMatrix.
For Example: Slot_5_in_1 (for input 1 of the SDI input card which is inserted in slot
5).