Power Failure Connections - Panasonic KX-NS500 Installation Manual

Hybrid ip-pbx
Hide thumbs Also See for KX-NS500:
Table of Contents

Advertisement

4.12 Power Failure Connections

4.12 Power Failure Connections
When the power supply to the PBX and/or Expansion Unit fails, power failure transfer (PFT) will switch from
the current connection to the Power Failure Connection. Refer to "5.6.2 Power Failure Transfer" in the Feature
Guide for further information.
The table below shows PFT support Cards and PFT support ports.
KX-NS500
Pre-installed LCOT6
Pre-installed MCSLC16
KX-NS520
Optional card KX-NS5180
Pre-installed MCSLC16
The table below shows the maximum number of PFT connections for each stacking configurations.
KX-NS500
(Pre-installed)
2
Note
A trunk conversation established during power failure can be maintained even when the power returns and
the connection is switched back to the normal configuration from the Power Failure Connection.
Power Failure Connection
In the case of KX-NS500
In the event of a power failure, a specific SLT port is automatically supplied power through the CO port. The
PFT ports are the port 1-2 (on pre-installed MCSLC16) and port 1-2 (on pre-installed LCOT6).
To CO1, CO2
176
Installation Manual
PFT support Cards
KX-NS500
(Maximum)
w/1 KX-NS520
2
To SLT1, SLT2
Port 1-2
Port 1-2
Port 1-4
Port 1-4
KX-NS500
w/2 KX-NS520s
6
PFT support ports
KX-NS500
w/3 KX-NS520s
10
KX-NS500
14

Advertisement

Table of Contents
loading

Table of Contents