Download  Print this page

Advertisement

International English
Parameter
Number
r0018
Firmware version
Displays the version number of the installed firmware.
r0021
CO: Actual frequency
r0025
CO: Actual output voltage
Displays the rms., voltage applied to the motor.
r0026
CO: Actual DC-link voltage
r0027
CO: Actual output current
Displays the rms. value of the motor current (A)
r0034
CO: Motor temperature (I
Displays the calculated motor temperature as a percentage of the maximum allowed value.
Note:
A value of 100% means that the motor has reached its maximum allowed operating
temperature. When this occurs the inverter will attempt to reduce the motor loading as
defined by parameter P0610 (Level 3).
r0039
CO: Energy consumpt. Meter
Displays the electrical energy used by the drive since the display was last reset (see P0040)
Note:
Value will get reset when P3900=1 (during quick commissioning), or when P0970=1 (factory
reset) or by using P0040.
P0040
Reset energy consumption meter
Resets energy consumption display to zero.
Possible Settings:
0 = No reset
1 = Reset r0039 to 0
Note:
Reset occurs when "P" is pressed.
50
Parameter Name
2
t)
5. SYSTEM PARAMETERS
Min
Max
[Default]
Units
-
-
[0]
-
-
-
[-]
Hz
-
-
[-]
V
-
-
[-]
V
-
-
[-]
A
-
-
[-]
%
0
-
[0]
kW
0
1
[0]
-
MICROMASTER 420 Operating Instructions
6SE6400-5AA00-0BP0
♦ ♦ ♦ ♦ P0003 User
Access Level
♦ ♦ ♦ ♦ P0004 Setting
♦ ♦ ♦ ♦ Changeable
♦ ♦ ♦ ♦ Status
1
2
2
13
2
13
2
2
2
13
2
3
2
2
2
2

Advertisement

Comments to this Manuals

Symbols: 0
Latest comments: