8.13.3 PROFIdrive area
● 915
Sub-Index
Item
Name
Data type
Access
Default setting
Detail
0x00
Detail
0x01
Detail
0x02
Detail
-
0x09
● 916
Sub-Index
Item
Name
Data type
Access
Default setting
Detail
0x00
Detail
0x01
Detail
0x02
Detail
-
0x09
● 922
Sub-Index
Item
-
Name
Data type
Access
Default setting
Detail
Description
Selection switch for DO IO Data in the setpoint telegram
ARRAY of UINT
R
0
This area displays P160 - P169 of WJ200 / WL200.
0x0000
: STW1
The others : Modbus register No. of WJ200 / WL200
0x0000
: NSOLL_A
The others : Modbus register No. of WJ200 / WL200
0x0000
: Unused
The others : Modbus register No. of WJ200 / WL200
Description
Selection switch for DO IO Data in the actual value telegram
ARRAY of UINT
R
0
This area displays P170 - P179 of WJ200 / WL200.
0x0000
: ZSW1
The others : Modbus register No. of WJ200 / WL200
0x0000
: NIST_A
The others : Modbus register No. of WJ200 / WL200
0x0000
: Unused
The others : Modbus register No. of WJ200 / WL200
Description
Telegram selection
UINT
R
1
This area displays telegram number that WJ-PN is communicating.
1
: Standard telegram 1
103 : WJ-PN telegram 103
104 : WJ-PN telegram 104
105 : WJ-PN telegram 105
47