Chassis Installation
a) Locate the PFU bay labeled Power Filter Unit 1 on the lower-left rear of the chassis.
b) Use a Phillips #2 screwdriver to loosen the four screws that secure the PFU in to the chassis.
c) Grasp the handle on the PFU and gently pull the PFU toward you. The PFU should slide easily out of the chassis.
Place it to the side for re-installation later.
d) Repeat step b and step c for the PFU located in the bay labeled Power Filter Unit 2 located on the lower-right side
of the chassis.
Step 4
Proceed to either the
page
58, based on the mounting option you are using.

Flush Mount Installation of the Chassis

Follow the instructions below to perform the flush mount installation of the chassis.
Step 1
Position the chassis in the equipment rack so that the flanges of the mounting brackets at the front of the chassis are flush
with the mounting rails of the equipment rack.
Step 2
Mount the chassis to the rails of the equipment rack. Use the hardware that was supplied with the equipment rack. Begin
with the two bottom holes and work your way up until all four holes on each flange are secured.
Flush Mount Installation of the Chassis, on page 57
Flush Mount Installation of the Chassis
or
Mid-Mount Installation of the Chassis, on
ASR 5000 Installation Guide
57