Troubleshooting
WARNING:
BEFORE TROUBLESHOOTING.
Problem
Vacuum will not operate
Dust comes out from motor cover.
Reduced efficiency and
motor/speed vibration.
TO REDUCE THE RISK OF ELECTRIC SHOCK-UNPLUG
Possible Causes
1) No power supply.
2) Faulty power cord.
3) Collection tank is full.
4) Switch in the wrong position
1) The cartridge filter is
missing or damaged.
1) There is a blockage in the
nozzle, hose, or the tank
inlet. The dust filter is
clogged by fine dust.
13
Corrective Action
1) Check power supply – cord,
breakers, fuses.
2) Unplug and check the power
cord. If damaged, have it
repaired by a professional.
3) Empty collection tank.
4) Press the ON 'I' button on
the power head.
1) Attach or replace the
cartridge filter.
1) Check nozzle, hose and
tank inlets for blockage.
Take off the filter and clean it.
Or install new cartridge filter.
Need help?
Do you have a question about the 125.17608 and is the answer not in the manual?
Questions and answers