Emerson Oxymitter 5000 Instruction Manual page 207

Oxygen transmitter
Hide thumbs Also See for Oxymitter 5000:
Table of Contents

Advertisement

Instruction Manual
IM-106-350, Rev 2.2
July 2008
Index
Parameter
Number
BLOCK_ALM
BLOCK_ERR
BYPASS
CAS_IN
CONTROL_OPTS
CONTROL_OPTS
DV_HI_ALM
DV_HI_LIM
DV_HI_PRI
DV_LO_ALM
DV_LO_LIM
DV_LO_PRI
ERROR
FF_ENABLE
FF_GAIN
FF_SCALE
FF_VAL
GAIN
GRANT_DENY
HI_ALM
HI_HI_ALM
HI_HI-LIM
HI_HI_PRI
HI_LIM
HI_PRI
IN
LO_ALM
LO_LIM
LO_LO_ALM
LO_LO_LIM
Units
44
None
06
None
17
None
18
EU of PV_SCALE
13
None
13
None
64
None
57
EU of PV_SCALE
56
None
65
None
59
EU of PV_SCALE
58
None
67
EU of PV_SCALE
70
None
42
None
41
None
40
EU of FF_SCALE
23
None
12
None
61
None
60
None
49
EU of PV_SCALE
48
None
51
EU of PV_SCALE
50
None
15
EU of PV_SCALE
62
None
53
EU of PV_SCALE
63
None
55
EU of PV_SCALE
Description
The block alarm is used for all configuration, hardware, connection failure, or
system problems in the block. The cause of the alert is entered in the
subcode field. The first alert to become active will set the active status in the
status parameter. As soon as the Unreported status is cleared by the alert
reporting task, and other block alert may be reported without clearing the
Active status, if the subcode has changed.
This parameter reflects the error status associated with the hardware or
software components associated with a block. It is a bit string so that multiple
errors may be shown.
Used to override the calculation of the block. When enabled, the SP is sent
directly to the output.
The remote setpoint value from another block.
Allows you to specify control strategy options. The supported control options
for the PID block are Track enable, Track in Manual, SP-PV Track in Man,
SP-PV Track in LO or IMAN, Use PV for BKCAL OUT, and Direct Acting.
Allows you to specify control strategy options. The supported control options
for the PID block are Track enable, Track in Manual, SP-PV Track in Man,
SP-PV Track in LO or IMAN, Use PV for BKCAL OUT, and Direct Acting
The DV HI alarm data, which includes a value of the alarm, a timestamp of
occurrence, and the state of the alarm.
The setting for the alarm limit used to detect the deviation high alarm
condition.
The priority of the deviation high alarm.
The DV LO alarm data, which includes a value of the alarm, a timestamp of
occurrence, and the state of the alarm.
The setting for the alarm limit use to detect the deviation low alarm condition.
The priority of the deviation low alarm.
The error (SP-PV) used to determine the control action.
Enables the use of feedforward calculations.
The feedforward gain value. FF_VAL is multiplied by FF_GAIN before it is
added to the calculated control output.
The high and low scale values, engineering units code, and number of digits
to the right of the decimal point associated with the feedforward value
(FF_VAL).
The feedforward control input value and status.
The proportional gain value. This value cannot = 0.
Options for controlling access of host computers and local control panels to
operating, tuning, and alarm parameters of the block. Not used by the device.
The HI alarm data, which includes a value of the alarm, a timestamp of
occurrence, and the state of the alarm.
The HI HI alarm data, which includes a value of the alarm, a timestamp of
occurrence, and the state of the alarm.
The setting for the alarm limit used to detect the HI HI alarm condition.
The priority of the HI HI Alarm.
The setting for the alarm limit used to detect the HI alarm condition.
The priority of the HI alarm.
The connection for the PV input from another block.
The LO alarm data, which includes a value of the alarm, a timestamp of
occurrence, and the state of the alarm.
The setting for the alarm limit used to detect the LO alarm condition.
The LO LO alarm data, which includes a value of the alarm, a timestamp of
occurrence, and the state of the alarm.
The setting for the alarm limit used to detect the LO LO alarm condition.
Oxymitter 5000
E-3

Advertisement

Table of Contents

Troubleshooting

loading