Feed Water Supply - GE PNRQ15RBL Owner's Manual & Installation Instructions

Ge profile reverse osmosis filtration system
Table of Contents

Advertisement

Available languages

Available languages

Feed Water Supply

Check and comply with local plumbing codes as you plan, then install a cold feed water supply fitting.
A. PREFERRED INSTALLATION
Utilizing existing kitchen sink water supply valve and
removable faucet tubing.
A typical connection using the included water supply
fitting is shown in the illustration below.
1. Close the water shut-off valve that is immediately
in front of the supply tube and open the faucets to
drain water from the sink cold water pipe.
2. Remove the nut that connects the cold water faucet
to the supply tube. Some water may spill out.
NOTES:
• Be sure to turn off the water supply and open a
faucet to drain the pipe.
• Make sure the gasket is installed in the water
supply fitting.
Cold
Water
Faucet
Stud
Cold
Water Pipe
Cold Water Shut-Off
3. Hand-tighten the water supply fitting onto the cold
water faucet. Be sure the gasket, as shown, is
in place before final assembly. Finish tightening
with an adjustable wrench. Be careful not to
overtighten or cross-thread, since damage to
the threads can occur. Make sure the 1/4" quick
connection is not against a wall that causes the
supply tubing connection to bend. A quarter
turn to tighten or loosen the adapter may be
necessary to avoid this.
4. Reconnect faucet tubing line to the fitting.
5. Install tubing. (See Installing the Tubing section.)
49-6000065
Installation Instructions
Gasket
Water Supply Fitting
1/4" Tubing to
Water Filter Inlet
Fig. 1
B. OPTIONAL INSTALLATION 1
Utilizing existing kitchen sink water supply valve (A)
and removable faucet tubing (B).
1.
Refer to illustration below to complete assembly
depending on supply valve size (A).
2.
Close the cold water supply valve (A) under the
sink.
3.
Unscrew the flexible tubing line (B) from
the supply valve (A) that connects to the
COLD water riser.
NOTE: For rigid pipe, see D. Optional Rigid Pipe
Installation on page 11.
Note Adapter (C) orientation:
3/8-inch installation—Rounded end of adapter (C)
connects to supply valve (A).
1/2-inch installation—Rounded end of adapter (C)
connects to coupling (D), then to existing faucet
tubing (B).
For 3/8" Plumbing
(B) Faucet
tubing line (not
included)
(D)
Coupling
(C)
(F) Inlet valve
Adapter
(G)
Gasket
(F) Inlet valve
(A) Cold water
supply valve
(not included)
For 1/2" Plumbing
(B) Faucet
tubing line
(H)
(not included)
Ferrule
(D)
Coupling
(G) Gasket
(I) Nut
(C) Adapter
(G) Gasket
(A) Cold water
supply valve
(not included)