ASSIGNING USER CODE AUTHORITY LEVELS

Assign authority levels to users by following the steps below. Assign user codes before assigning authority
levels. Your system must be in the disarmed state to change user code authority levels.
Step 1
Press [r]-[6].
Step 2
Enter a ["Master Arm/Disarm Code"].
NOTE: Someone changing the authority of another person can only add or remove
partition authorization for partitions to which they have access.
Step 3
Enter the 2-digit (applies to NX4/6/8) or 3-digit (applies to NX8E) user number. Always use
leading zeros when necessary, i.e. "004" for user number 4.
Step 4
The LCD will now prompt you for the attributes in the following chart :
PROMPT
Outputs used?
Open / Close Rprt?
Bypass enable?
Arm / Disarm?
Master code?
Sched arm only?
Arm only?
Reserved
Output 4 ?
Output 3 ?
Output 2 ?
Output 1?
Step 5
NOTE: The LCD will now display all of the partitions to which this user has access. If you
wish to remove a partition, press the partition number on the keypad, and the display will
mark that partition with a (-) hyphen indicating access has been removed. If you wish to re-
establish user access to the partition, press the partition number again.
Step 6
Press [r] to save the data. The LCD will then prompt you for the next user code.
Step 7
If another user code needs to be programmed, return to Step 3. If not, press [#] to exit this
feature without saving the data.
NX-148E User manual
DO NOT CHANGE THIS SEGMENT!
(These are for use by a professional installer
only.)
0=No
1=Yes
Your keypress will apply to the user code you
entered in Step 3.
If these messages appear on the LCD screen, press
the [r] key until you return to the prompt for the user
code or until you exit this adjust mode.
Page 14
g
GE Security
04/10/04

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents