Yamaha TYROS 2 Service Manual page 81

Digital workstation / monitor speaker
Hide thumbs Also See for TYROS 2:
Table of Contents

Advertisement

19
019:EQ Low Chk
20
020:EQ Mid Chk
21
021:EQ High Chk
22
022:SP MUTE Chk
23
023:Mute Chk
25
025:MIC L Chk
26
026:MIC R Chk
3)
Connect a level meter to the [WOOFER] jack (R) with a load of 470
ohm and set the [MASTER VOLUME] knob to maximum.
(L: Pin6-Pin3, R: Pin5-Pin3, Pin3: GND)
Confirm the noise levels are as follows.
L:
-80.0dBu or less
R:
-80.0dBu or less
4)
Connect a level meter to the [LINE OUT] jack (SUB1) with a load of
10k ohm and set the [MASTER VOLUME] knob to maximum.
Confirm that the noise leve is -80.0 dBu or less.
5)
Connect a level meter to the [LINE OUT] jack (SUB2) with a load of
10k ohm and set the [MASTER VOLUME] knob to maximum.
Confirm that the noise leve is -80.0 dBu or less.
Checks the frequency of EQ LOW.
The sine wave of about 65.4Hz is output from the [LINE OUT] jack (MAIN
L/L+R, MAIN R, SUB1, SUB2).
Checks the frequency of EQ MID.
The sine wave of about 523Hz is output from the [LINE OUT] jack (MAIN L/
L+R, MAIN R, SUB1, SUB2).
Checks the frequency of EQ HIGH.
The sine wave of about 4186Hz is output from the [LINE OUT] jack (MAIN
L/L+R, MAIN R, SUB1, SUB2).
Checks the SP mute.
When the test is executed, the sine wave of about 4186Hz is output from
the [LINE OUT] jack (MAIN L/L+R, MAIN R).
Confirm that the 'ON' and 'OFF' of SP MUTE can be toggled by pressing
the TAB[<] button or the TAB[>] button.
Checks the mute.
When the test is executed, the sine wave of about 4186Hz is output from
the [LINE OUT] jack (MAIN L/L+R, MAIN R).
Confirm that the 'ON' and 'OFF' of MUTE can be toggled by pressing the
TAB[<] button or the TAB[>] button.
Checks the input levels of MIC/LINE IN L.
Connect a level meter to the [AUX OUT/LOOP SEND] jack (L/L+R, R) with
a load of 10k ohm.
Apply a 1kHz sine wave at -45dBu to the [MIC/LINE IN L/L+R] jack with a
load of 10k ohm, and set the [INPUT VOLUME] and [MIC/LINE IN TRIM]
knobs to maximum.
Confirm that the level meter reads the following value.
L:
+13.0
2dBu
Checks the input levels of MIC/LINE IN R.
Connect a level meter to the [AUX OUT/LOOP SEND] jack (L/L+R, R) with
a load of 10k ohm.
Apply a 1kHz sine wave at -45dBu to the [MIC/LINE IN R] jack with a load
of 10k ohm, and set the [INPUT VOLUME] and [MIC/LINE IN TRIM] knobs
to maximum.
Confirm that the level meter reads the following value.
R:
+13.0
2dBu
Tyros2
81

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Trs-ms02

Table of Contents