Troubleshooting

WARNING
To reduce the risk of electric shock, turn power switch off and disconnect plug from
electrical outlet before performing maintenance or troubleshooting checks.
Problem
Vacuum
cleaner
won't run
Vacuum
cleaner won't
pick up dirt
10
www.BISSELL.com
Possible causes
Power cord not plugged in
Blown fuse/tripped breaker
Dirt container is full
Filter dirty
Hose not secure
Dirt container not in place
Vacuum path clogged
Rotating power brush drive belt
broken
Drive belt stretched
Floor brush bristles worn
Floor brush jammed
Remedies
Check electrical plug
Check/replace fuse or reset breaker
Empty dirt container
Check, remove debris or clean
Check to be sure hose is snapped
into place at both ends
Remove dirt container and secure into
place, making sure you hear a click
Visually check air passageway, hose
inlet, and hose for anything that
might be obstructing the vacuum
path. Carefully remove blockage.
Replace drive belt
Check drive belt area and remove
obstructions. Replace drive belt if
necessary
Replace floor brush
Remove floor brush and clean debris
from brush and ends. Check drive
belt for any damage