Chapter 4 Front Panel Operation
Menu Item
CC Pkt 1, CC Pkt 2
LOI Action
Setting Up Transcoding
To set up the transcode channel:
1
Verify that you are receiving a valid signal and that you have set up the channels
that you want to transcode.
2
Go to Setup: Outputs: TS Out: DPM: ASI, and set the Output Mode to
Transcoding. You will be prompted to Resync All for the selected output. This
resynchronizes the inputs to outputs for the current PMT according to the service
assignments and the PIDs for the PE.
3
Press MENU to exit the menu and save the data. If the changes cannot be saved/
made, a message will be displayed indicating "Bad configuration data". In this
case, the menu will revert to the previously saved configuration. Note: When
remapping an input program channel to an output channel, ensure that the PIDs
are mapped to different PIDs to avoid PID collisions.
4
If desired, set a program channel for the second transcoder channel, PE2, and
repeat step 2. See LCD Symbol (on page 40) for more information on assigning a
program channel to a PE.
Inband
Menu Item
PE
Apply Inband
112
Description
This selects the order to output
the closed caption packets on
the transcoded SD output.
This selects the transcode Loss
Of Input (LOI) Action, which is
the action that the transcoder
takes when there is a loss of
input signal.
Description
This selects the transcoder
index as referenced by DPM.
This applies the uplink
parameters for transcoding,
such as bitrate, GOP and
resolution, to the local
transcoder settings for the
selected program entry. This is
only supported with an uplink
that uses uplink transcoding
controls for the user address of
the selected program entry.
Parameters
None, SCTE-20, or CEA 708. The
default is CEA 708.
No Output or Black Output
Parameters
1 to 8
Yes or No
OL-31980-01