Download Print this page
Panasonic FX-100 Series Instruction Manual

Panasonic FX-100 Series Instruction Manual

Digital fiber sensor

Advertisement

Quick Links

INSTRUCTION MANUAL
Digital Fiber Sensor FX-100 series
MJE-FX100C No.0035-66V
Thank you very much for purchasing Panasonic products. Read this Instruction Manual
carefully and thoroughly for the correct and optimum use of this product. Kindly keep
this manual in a convenient place for quick reference.
WARNING
● Never use this product as a sensing device for personnel protection.
● In case of using sensing devices for personnel protection, use products which
meet laws and standards, such as OSHA, ANSI or IEC etc., for personnel protec-
tion applicable in each region or country.
1
PART DESCRIPTION
ON key / Set value UP key
OFF key / Set value DOWN key
• Selection of setting contents
• Selection of setting contents
• Settings in teaching mode
• Settings in teaching mode
Operation indicator
(Orange)
Digital display (Green)
MODE key
(Threshold value)
• Selection of setting items
• Confirmation of set contents
Digital display (Red)
(Incident light intensity)
2
MOUNTING
<When using a DIN rail>
How to mount the amplifier
1. Fit the rear part of the mounting section of the amplifier
on DIN rail.
2. Press down the rear part of the mounting section of the
2
unit on the DIN rail and fit the front part of the mounting
1
section to the DIN rail.
35mm width DIN rail
How to remove the amplifier
1
2
1. Push the amplifier forward.
2. Lift up the front part of the amplifier to remove it.
Note: Take care that if the front part is lifted without pushing the amplifier forward,
the hook on the rear portion of the mounting section is likely to break.
<When using screws with washers>
● Use M3 screws with washers for mounting. The tighten-
ing torque should be 0.5N·m or less.
M3 screw with
washer
How to connect the fiber cable
Be sure to fit the attachment to the fibers first before inserting the fibers to the ampli-
fier. For details, refer to the Instruction Manual enclosed with the fibers.
1. In cover open condition, snap the fiber lock lever down,
3
till it stops completely.
2. Insert the fiber cables slowly into the inlets until they
1
stop. (Note 1)
Fiber lock lever
2
3. Return the fiber lock lever to the original position, till it
Fiber
stops.
Notes: 1) In case the fiber cables are not inserted to a position where they stop, the sensing range reduces. Since a
flexible fiber is easily bent, take care when it is inserted.
2) With the coaxial reflective type fiber, such as, FD-42G or FD-61G, insert the single-core fiber cable into the
beam-emitting inlet “P” and the multi-core fiber cable into the beam-receiving inlet “D.” If they are inserted in
reverse, the sensing performance will deteriorate.
3
WIRING
Connection method
Cable with
connector
CN-14A-C□
● Insert the cable with connector CN-14A-C□ into this
product’s connector area as shown in the right figure.
Disconnection method
Cable with
connector
● Pressing the release lever of the cable with connector,
CN-14A-C□
pull out the connector.
Note: Take care that if the connector is pulled out without pressing the release
lever, cable or connector may break.
<Connector pin arrangement>
Connector pin No.
Terminal name
1
1
+V
2
2
Output
3
3
External input
4
4
0V
4
I/O CIRCUIT DIAGRAMS
NPN output type
Color code of cable with connector
Connector pin No.
(Brown) +V
Load
(Black) Output
+
12 to 24V DC
8V
±10%
-
(White) External input
*1
(Blue) 0V
PNP output type
Color code of cable with connector
Connector pin No.
(Brown) +V
*2
(White) External input
+
12 to 24V DC
±10%
-
(Black) Output
Load
(Blue) 0V
*1
*2
Non-voltage contact or NPN open-collector transistor
Non-voltage contact or PNP open-collector transistor
or
or
High [+4V to +V DC (Sink current 0.5 to 3mA or less)]: Valid
High (+8V to +V DC or Open): Invalid
Low (0 to +0.6V DC or Open): Invalid
Low [(0 to +2V DC (Source current 0.5mA or less)] : Valid
5
RUN MODE
<Digital display>
● When turning ON the power, the product name is indicated on the green digital dis-
play, while the emission frequency is indicated on the red digital display. Then switch-
es into RUN mode [digital display (green: threshold value, red: incident light intensity)].
<When turning ON the power>
<RUN mode>
AUTO
Threshold
Incident light
Product
Emission
value
intensity
name
frequency
● When selecting emission halt in the external input setting mode and receiving the
signal externally, “
” is indicated on the red digital display.
● When selecting ECO in the external input setting mode, key operation on the main
body is invalid during external input.
● When selecting 2-point teaching in the external input setting mode, “
” is indi-
cated on the green digital display after inputting the first point.
● When ECO setting mode is ON, the digital display turns off in approx. 20 sec. In
case of lighting up the digital display again, press any key for 2 sec. or more.
PRO MODE.”
● For the settings of external input and ECO, refer to “
Threshold value fine adjustment function
● Fine adjustment of threshold value can be done when in RUN mode.
● Press the set value UP key or set value DOWN key to change threshold value.
(Hold down the key to make the value change faster.)
● The threshold value is stored after 3 sec.
When in RUN mode
Threshold
Incident light
value
intensity
Keylock function
● The keylock function prevents key operations so that the conditions set in each setting
mode are not inadvertently changed.
● In the keylock condition, “
” is displayed when pressing any key.
<Keylock set>
<When in RUN mode>
AUTO
Press for 2 sec.
<Keylock released>
<When in RUN mode>
AUTO
AUTO
Press for 2 sec. or more
6
SETTING MODE
● Setting mode appears after pressing MODE key for 2 sec. in RUN mode.
● RUN mode appears when MODE key is pressed for 2 sec. while setting and the
changed contents have been set.
● Make sure to return to RUN mode before turning OFF the power. If the power is
turned OFF while setting, the changed contents have not been set.
<Setting mode>
Press for 2 sec.
Press for 2 sec.
AUTO
<Teaching mode>
For details, refer to “
TEACHING MODE.”
<Output operation setting mode>

Advertisement

loading

Summary of Contents for Panasonic FX-100 Series

  • Page 1 Color code of cable with connector Connector pin No. MJE-FX100C No.0035-66V (Brown) +V Thank you very much for purchasing Panasonic products. Read this Instruction Manual Load (Black) Output carefully and thoroughly for the correct and optimum use of this product. Kindly keep 12 to 24V DC this manual in a convenient place for quick reference.
  • Page 2 <For output ON when in object absent condition> <Teaching mode> <Teaching mode> Thru-beam type Reflective type • Press ON key in object <Output operation setting mode> absent condition. Mark Base Light received condition Light interrupted condition (Dark-ON) (Light-ON) • The first incident light intensity is set and indicated on the green digital display. Cancellation of the setting for the first incident light intensity is possible when AUTO MODE key is pressed.
  • Page 3 <External input setting mode> EXTERNAL INPUT SETTING ● When selecting emission halt in the external input setting mode and receiving the <Threshold value follow-up cycle setting mode> signal externally, “ ” is indicated on the red digital display. ● When selecting ECO in the external input setting mode, key operation on the main body is invalid during external input. (Under 60 sec.) (OFF) (1 to 9 min. or less) (10 to 60 min. or less) ●...
  • Page 4 Notes: 5) When the present setting is out of the code setting range, “–” is shown. When “–” is selected, the set content Phone: +81-568-33-7861 FAX: +81-568-33-8591 of the digit is not changed. About our sale network, please visit our website. 6) The factory setting is “ .” PRINTED IN CHINA © Panasonic Industrial Devices SUNX Co., Ltd. 2012...

This manual is also suitable for:

Mje-fx100cFx-101Fx-102Fx-101-cc2Fx-101pFx-101p-cc2 ... Show all