SUB200 (SCS200.7sys)
Parameter
Specification
ATO Turn-on time
Auto Mute/ Turn-OFF Time
Power on Delay time
Transients/Pops
ATO Transient
Turn-on Transient
Turn-off Transient
Efficiency
Stand-by Input Power
Power Cons.@rated power
Power Cons.@rated power
Protection
Short Circuit Protection
Thermal Protection
65 deg. C
DC Offset Protection
Line Fuse Rating
120VAC
230VAC
QA Test
Unit
Limits
5
ms
Functional
15
minutes
Functional
3
sec.
Functional AC Power Applied
5
mV-peak
10
100
50
mV-peak
50
mV-peak
100
12
Watts
13
180
Watts
187
195
Watts
200
Functional Direct short at output
YES
--
--
Functional @1/8 max unclipped Power
YES
--
Functional DC present at Speaker Out leads
2.5
Amps
1.25
Amps
Conditions
Amp connected and AC on, then input
signal applied
T before muting, after signal is
removed
@ Speaker Outputs
@ Speaker Outputs
@ Speaker Outputs
@ nom. line voltage
@ 120V-60 Hz (Nom.line voltage)
@ 230V-50 Hz (Nom.line voltage)
Type-T or Slo Blo
Type-T or Slo Blo
3
Notes
Auto turn of time (T) must be 10 > T <15
AC Line cycled from OFF to ON
AC Line cycled from ON to OFF
Maximum allowable input power under
nominal Input voltage and frequency,
HOT or COLD operation.
90 Watts @ 4 Ohms nominal line voltage
90 Watts @ 4 Ohms nominal line voltage
Temperature rise should not exceed 35K
rise
Relay or crowbar (for driver/fire
External fuse with UL/SEMKO rated
holder
External fuse with UL/SEMKO rated
holder