Chapter 3
Communication Ports
WARNING!
Electric shock hazard – risk of serious personal injury and/or equipment interference. If shielded
cables are used, make sure the shielded cables do not form a ground loop via the shield wire and the
RJ45 receptacles at either end. Ground loops can cause excessive noise and interference, but more
importantly, create a potential shock hazard that can result in serious injury.
Each port features a Speed and Link LED that indicates the state of the port.
LED
Speed
Link
The following is the pin-out for the RJ45 male connectors:
8
Figure 9: RJ45 Ethernet Port Pin Configuration
For specifications on the available copper Ethernet ports, refer to
Specifications".
12
State
Yellow
Off
Yellow (Solid)
Yellow (Blinking)
Off
1
Description
The port is operating at maximum speed
The port is not operating at maximum speed
Link established
Link activity
No link detected
Name
Pin
10/100TX
100FX
1
RX+
2
RX-
3
TX+
4
Reserved (Do
Not Connect)
5
Reserved (Do
Not Connect)
6
TX-
7
Reserved (Do
Not Connect)
8
Reserved (Do
Not Connect)
Section 4.4, "Copper Ethernet Port
RUGGEDCOM i802
Installation Guide
Description
1000TX/SX/LX
BI_DA+
Receive Data+
or Bi-Directional
Pair A+
BI_DA-
Receive Data-
or Bi-Directional
Pair A-
BI_DB+
Transmit Data+
or Bi-Directional
Pair B+
BI_DC+
Transmit Data+
or Bi-Directional
Pair C+
BI_DC-
Receive Data-
or Bi-Directional
Pair C-
BI_DB-
Transmit Data-
or Bi-Directional
Pair B-
BI_DD+
Receive Data-
or Bi-Directional
Pair D+
BI_DD-
Receive Data-
or Bi-Directional
Pair D-