Kenwood CK 232 DFA Instructions For Use - Installation Advice page 38

Gas cooker with electric double oven
Table of Contents

Advertisement

RESTRAINING CHAIN
Installation to Natural Gas
Installation to Natural Gas must conform to the Code of Practice, etc .
The supply pressure for Natural Gas is 20 mbar .
The installation must conform to the relevant British/European Standards .
Installation to LP Gas
When operating on Butane gas a supply pressure of 28-30 mbar is required .
When using Propane gas a supply pressure of 37 mbar is required .
The installation must conform to the relevant British/European Standards .
Warning: Only a suitably qualified and registered installer, also with technical knowledge
of electricity should install the appliance .
He should observe the Regulations and Codes of Practice governing such installation of
gas appliances .
Note: It is recommended that the gas connection to the appliance is installed with a flexible
hose connecting tube made to BS669 or EN 14800 .
38
Chain
security
holes
Fig . 10 .1
Cooker
Back of
the cooker
Rear wall