(3) Processing of file registerís block numbers
(a) When switching from the scan execution type program to the interrupt/fixed scan
execution type program
The CPU module saves the file register block numbers in the scan execution type program, and passes them
to the interrupt/fixed scan execution type program.
(b) When switching from the interrupt/fixed scan execution type program to the scan
execution type program
The CPU module restores the saved block numbers of the file register.
Execution program
Block No. of
file register
Save area
9 - 52
Switching
Scan execution
type program
Passed
Block 1
Saved
Block 0
Block 1
Figure 9.65 Saving and restoring file registerís block numbers
Interrupt/fixed scan
Restored
execution type
program
[RSET K0]
Block1
0
Block 1
Block 1
Scan execution
type program
Block 1
Restored
Block 1