(f) Displaying trace results
Read trace results form the CPU module and display the data.
1) Click the
Trace result PLC read
2) Click the
Trace result
The trace results shows the on/off status of each bit device for every sampling cycle and the current value of
each word device.
Specified devices are read when the condition selected in "Trigger point setup" (trigger condition) is established.
Therefore, when devices are sampled in every scan and the sampling is finished by trigger operation from a peripheral, the
data is sampled twice because timing of the sampling is the same with that of the establishment of trigger condition.
button on the screen shown in Figure 6.71 to read trace results.
button on the same screen to display the trace results read.
Figure 6.72 Trace result screen
Data when the trigger
conditions are satisfied.
Figure 6.73 Trace result
Data when trigger condition is met
CHAPTER6 FUNCTIONS
6 - 87
1
2
3
4
5
6
7
8