2. Attach one adapter to the gas pressure regulator and the other adapter to the gas shutoff valve. Tighten both
adapters, being certain not to move or turn the gas pressure regulator.
3. Use a ¹⁵⁄₁₆" combination wrench and an adjustable wrench to attach the flexible connector to the adapters.
IMPORTANT: All connections must be wrench-tightened. Do not make connections to the gas regulator too tight.
Making the connections too tight may crack the regulator and cause a gas leak. Do not allow the regulator to turn when
tightening fittings.
Complete Connection
1. Locate gas pressure regulator in the back of the range. IMPORTANT: Do not remove the gas pressure regulator.
2. Check that the gas pressure regulator shutoff valve is in the "ON" position. IMPORTANT: The factory default setting
is the "ON" position. If the range does not work, verify that the valve is in the "ON" position.
3. Open the manual shutoff valve in the gas supply line. The valve is open when the handle is parallel to the gas pipe.
09-May-2014 18:21:12 EDT | RELEASED
Use a connection fitting male ½´´to Range (see
In some European factories the letter "W" of the part code mentioned herein will be automatically
A).
replaced by the number "4000" (e.g. "W12345678" becomes "400012345678")