Compool Pool-Spa Switching System CP30 Installation Instructions Manual

Pool-spa switching system

Advertisement

Quick Links

SYSTEM START-UP
Apply power to the system.
At the LX-30 Power Center, check that the POWER Status Light has turned on.
If the status light is not on, check the 3 amp circuit breaker which is located above
the faceplate. Tripped circuit breaker is indicated by a white tab. Push to reset.
Turn the FILTER PUMP Service Switch "ON" and " O F F to verify that pump is
operating.
Return FILTER PUMP Service Switch t o "TIMER" position, and activate filter
7ump using the FILTER TIMER Dial.
t
the system incorporates a pool cleaner pump, activate pump using the
CLEANER TIMER Dial.
At the Remote Control, turn SPA Switch to "SPA position.
Check that Valve Actuators have rotated to correct positions. If either valve is
180" out of phase, flip toggle switch on rear of Valve Actuator from "ON1" to
"ON2" position.
Turn HEAT Switch to "SPA position, and check that heater has been activated.
Turn AUXl and AUX2 Switches "ON", and verify that auxiliary equipment has
been activated.
The system is now ready to be operated as desired.
a PAC FA6 Company
Cornpool, Inc.
599 Fairchild Drive
Mountain View
California 94043
800-458-2201
http ://www.c0mpo01.com
INSTALLATION INSTRUCTIONS
CP30 POOL-SPA SWITCHING SYSTEM
IMPORTANT SAFETY INSTRUCTIONS
All wiring must be performed by a qualified electrician.
Basic safety precautions and local codes should
always be followed when installing and using this
electrical equipment.
READ AND FOLLOW ALL INSTRUCTIONS.
WARNING : To reduce the risk of injury, do not
permit children to use this product unless they are
closely supervised at all times.
SAVE THESE INSTRUCTIONS.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Pool-Spa Switching System CP30 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Compool Pool-Spa Switching System CP30

  • Page 1 SYSTEM START-UP Apply power to the system. At the LX-30 Power Center, check that the POWER Status Light has turned on. If the status light is not on, check the 3 amp circuit breaker which is located above the faceplate. Tripped circuit breaker is indicated by a white tab. Push to reset. Turn the FILTER PUMP Service Switch "ON"...
  • Page 3 SYSTEM OPTIONS POOL CLEANER : For systems which incorporate a booster pump pool cleaner, it is possible to add a mechanical time clock for programming the daily cleaning cycles. Install 24-Hour Time Clock (model TMR-LX) into LX-30 faceplate at the CLEANER TIMER location, and plug into circuit board at CLNR TIMER socket, in accordance with instructions provided.
  • Page 4 EQUIPMENT LOCATION Select a convenient location to install the various components of the System. All electrical equipment must be located five feet or more from the water's edge : LX-30 Power Center at the equipment site. CVA-24 Valve Actuators at valves to be motorized. CP-30 Remote Control at convenient location indoors or outside.
  • Page 5 VALVE ACTUATORS Mount Valve Actuators (model CVA-24) to three-port valves in accordance with instructions printed on box. Run cables to low voltage compartment of LX-30 Power Center, and plug into circuit board at appropriate valve socket : Intake (suction) Valve to INT VLV socket. Return Valve to RET VLV socket.
  • Page 6 DUAL-THERMOSTAT GAS HEATER : Inside the gas heater, connect 3-conductor cable in parallel with the heater toggle switch (blue to POOL, black to COMMON and red to SPA). If the heater requires a fireman's switch, connect 2-conductor cable in series with the heater circuitry (at Fireman's Switch terminals if provided).

This manual is also suitable for:

Cp30

Table of Contents