GE T60 Instruction Manual page 537

Transformer protection system ur series
Hide thumbs Also See for T60:
Table of Contents

Advertisement

APPENDIX A
Table A–1: FLEXANALOG DATA ITEMS (Sheet 3 of 24)
ADDRESS
FLEXANALOG NAME
6296
SRC 3 Ig Angle
6297
SRC 3 I_0 Mag
6299
SRC 3 I_0 Angle
6300
SRC 3 I_1 Mag
6302
SRC 3 I_1 Angle
6303
SRC 3 I_2 Mag
6305
SRC 3 I_2 Angle
6306
SRC 3 Igd Mag
6308
SRC 3 Igd Angle
6336
SRC 4 Ia RMS
6338
SRC 4 Ib RMS
6340
SRC 4 Ic RMS
6342
SRC 4 In RMS
6344
SRC 4 Ia Mag
6346
SRC 4 Ia Angle
6347
SRC 4 Ib Mag
6349
SRC 4 Ib Angle
6350
SRC 4 Ic Mag
6352
SRC 4 Ic Angle
6353
SRC 4 In Mag
6355
SRC 4 In Angle
6356
SRC 4 Ig RMS
6358
SRC 4 Ig Mag
6360
SRC 4 Ig Angle
6361
SRC 4 I_0 Mag
6363
SRC 4 I_0 Angle
6364
SRC 4 I_1 Mag
6366
SRC 4 I_1 Angle
6367
SRC 4 I_2 Mag
6369
SRC 4 I_2 Angle
6370
SRC 4 Igd Mag
6372
SRC 4 Igd Angle
6400
SRC 5 Ia RMS
6402
SRC 5 Ib RMS
6404
SRC 5 Ic RMS
6406
SRC 5 In RMS
6408
SRC 5 Ia Mag
6410
SRC 5 Ia Angle
6411
SRC 5 Ib Mag
6413
SRC 5 Ib Angle
6414
SRC 5 Ic Mag
6416
SRC 5 Ic Angle
6417
SRC 5 In Mag
6419
SRC 5 In Angle
6420
SRC 5 Ig RMS
6422
SRC 5 Ig Mag
6424
SRC 5 Ig Angle
GE Multilin
UNITS
DESCRIPTION
Degrees
Source 3 ground current angle
Amps
Source 3 zero-sequence current magnitude
Degrees
Source 3 zero-sequence current angle
Amps
Source 3 positive-sequence current magnitude
Degrees
Source 3 positive-sequence current angle
Amps
Source 3 negative-sequence current magnitude
Degrees
Source 3 negative-sequence current angle
Amps
Source 3 differential ground current magnitude
Degrees
Source 3 differential ground current angle
Amps
Source 4 phase A current RMS
Amps
Source 4 phase B current RMS
Amps
Source 4 phase C current RMS
Amps
Source 4 neutral current RMS
Amps
Source 4 phase A current magnitude
Degrees
Source 4 phase A current angle
Amps
Source 4 phase B current magnitude
Degrees
Source 4 phase B current angle
Amps
Source 4 phase C current magnitude
Degrees
Source 4 phase C current angle
Amps
Source 4 neutral current magnitude
Degrees
Source 4 neutral current angle
Amps
Source 4 ground current RMS
Amps
Source 4 ground current magnitude
Degrees
Source 4 ground current angle
Amps
Source 4 zero-sequence current magnitude
Degrees
Source 4 zero-sequence current angle
Amps
Source 4 positive-sequence current magnitude
Degrees
Source 4 positive-sequence current angle
Amps
Source 4 negative-sequence current magnitude
Degrees
Source 4 negative-sequence current angle
Amps
Source 4 differential ground current magnitude
Degrees
Source 4 differential ground current angle
Amps
Source 5 phase A current RMS
Amps
Source 5 phase B current RMS
Amps
Source 5 phase C current RMS
Amps
Source 5 neutral current RMS
Amps
Source 5 phase A current magnitude
Degrees
Source 5 phase A current angle
Amps
Source 5 phase B current magnitude
Degrees
Source 5 phase B current angle
Amps
Source 5 phase C current magnitude
Degrees
Source 5 phase C current angle
Amps
Source 5 neutral current magnitude
Degrees
Source 5 neutral current angle
Amps
Source 5 ground current RMS
Amps
Source 5 ground current magnitude
Degrees
Source 5 ground current angle
T60 Transformer Protection System
A.1 PARAMETER LISTS
A-3
A

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents