Parameter Lists; Flexanalog Items; A.1.1 Flexanalog Items - GE T60 Instruction Manual

Transformer protection system ur series
Hide thumbs Also See for T60:
Table of Contents

Advertisement

APPENDIX A
Appendices
APPENDI X A Fl e xAnal o g and Fl e xI n t e ger Par a met e r s A.1Parameter Lists
A FlexAnalog parameter is an analog parameter.
FlexAnalog items are also viewable in a web browser. Enter the IP address of the UR, access the Device Information
Menu option, then the FlexAnalog Parameter Listing option. Entries displayed online depend on order code.
Table A–1: FLEXANALOG DATA ITEMS (Sheet 1 of 24)
ADDRESS
FLEXANALOG NAME
5792
RGF 1 Igd Mag
5794
RGF 1 Igr Mag
5796
RGF 2 Igd Mag
5798
RGF 2 Igr Mag
5800
RGF 3 Igd Mag
5802
RGF 3 Igr Mag
5804
RGF 4 Igd Mag
5806
RGF 4 Igr Mag
5808
RGF 5 Igd Mag
5810
RGF 5 Igr Mag
5812
RGF 6 Igd Mag
5814
RGF 6 Igr Mag
5824
Field RTD 1 Value
5825
Field RTD 2 Value
5826
Field RTD 3 Value
5827
Field RTD 4 Value
5828
Field RTD 5 Value
5829
Field RTD 6 Value
5830
Field RTD 7 Value
5831
Field RTD 8 Value
5832
Field TDR 1 Value
5834
Field TDR 2 Value
5836
Field TDR 3 Value
5838
Field TDR 4 Value
5840
Field TDR 5 Value
5842
Field TDR 6 Value
5844
Field TDR 7 Value
5846
Field TDR 8 Value
6144
SRC 1 Ia RMS
6146
SRC 1 Ib RMS
6148
SRC 1 Ic RMS
6150
SRC 1 In RMS
6152
SRC 1 Ia Mag
6154
SRC 1 Ia Angle
6155
SRC 1 Ib Mag
6157
SRC 1 Ib Angle
6158
SRC 1 Ic Mag
6160
SRC 1 Ic Angle
6161
SRC 1 In Mag
6163
SRC 1 In Angle
6164
SRC 1 Ig RMS
GE Multilin
UNITS
DESCRIPTION
Amps
Restricted ground fault 1 differential ground current magnitude
Amps
Restricted ground fault 1 restricted ground current magnitude
Amps
Restricted ground fault 2 differential ground current magnitude
Amps
Restricted ground fault 2 restricted ground current magnitude
Amps
Restricted ground fault 3 differential ground current magnitude
Amps
Restricted ground fault 3 restricted ground current magnitude
Amps
Restricted ground fault 4 differential ground current magnitude
Amps
Restricted ground fault 4 restricted ground current magnitude
Amps
Restricted ground fault 5 differential ground current magnitude
Amps
Restricted ground fault 5 restricted ground current magnitude
Amps
Restricted ground fault 6 differential ground current magnitude
Amps
Restricted ground fault 6 restricted ground current magnitude
---
Field RTD 1 value
---
Field RTD 2 value
---
Field RTD 3 value
---
Field RTD 4 value
---
Field RTD 5 value
---
Field RTD 6 value
---
Field RTD 7 value
---
Field RTD 8 value
---
Field TDR 1 value
---
Field TDR 2 value
---
Field TDR 3 value
---
Field TDR 4 value
---
Field TDR 5 value
---
Field TDR 6 value
---
Field TDR 7 value
---
Field TDR 8 value
Amps
Source 1 phase A current RMS
Amps
Source 1 phase B current RMS
Amps
Source 1 phase C current RMS
Amps
Source 1 neutral current RMS
Amps
Source 1 phase A current magnitude
Degrees
Source 1 phase A current angle
Amps
Source 1 phase B current magnitude
Degrees
Source 1 phase B current angle
Amps
Source 1 phase C current magnitude
Degrees
Source 1 phase C current angle
Amps
Source 1 neutral current magnitude
Degrees
Source 1 neutral current angle
Amps
Source 1 ground current RMS
T60 Transformer Protection System
A.1 PARAMETER LISTS

A.1.1 FLEXANALOG ITEMS

A-1
A

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents