Suzuki GZ250 Marauder Service Manual page 70

Hide thumbs Also See for GZ250 Marauder:
Table of Contents

Advertisement

ENGINE
3-33
NOTE:
Install the cylinder head cover to its original position.
Tighten the cylinder head cover bolts evenly and diagonally
to the specified torque.
Cylinder head cover bolt: 10 N ■ m (1.0 kg-m, 7.0 Ib-ft)
NOTE:
Do not rotate the camshaft with the plastigauge in place.
Remove the cylinder head cover and measure the width of the
compressed plastigauge using the envelope scale. This
measurement should be taken at the widest part of the
compressed plastigauge.
Service Limit
Camshaft-Journal oil clearance: 0.150 mm
If t he camshaft journal oil clearance exceeds the limit,
measure the inside diameter of the camshaft journal holder
and outside diamet er of the camshaft journal. Replace the
camshaft or the cylinder head depending upon which one
exceeds the specific ation.
09900-22403: Small bore gauge
Standard
Camshaft journal holder I.D.
(Right side) : 25.012-25.025 mm (0.9847-0.9852 in)
(Left side)
09900-20205: Micrometer (0-25 mm)
Standard
Camshaft journal O.D.
(Right side) : 24.959-24.980 mm (0.9826-0.9835 in)
(Left side)
CAMS HAFT RUNOUT
Measure the runout using a dial gauge. Replace the camshaft
if the runout exceeds the limit.
09900-20606: Dial gauge (1/100 mm)
09900-20701: Magnetic stand 09900-21304:
V-block set (100 mm)
Service Limit
Camshaft runout: 0.10 mm (0.004 in)
Downloaded from
www.Manualslib.com
(0.0059 in)
: 20.012-20. 025 mm (0. 7879-0.7884 in)
: 19.959-19.980 mm (0.7858-0.7866 in)