22.3.3 Shield Termination Technique - Method A.2 (Daisy Chain)
In rare situations where more braids need to be terminated for a connector than three per ring terminal it is
allowable to daisy chain a maximum of two shields together before coming to the ring terminal
(Figure 22-8). All other restrictions and instructions for the shield termination technique set forth for
Method A.1 are still applicable.
NOTE
The maximum length of the combined braids should be approximately 4 inches.
Figure 22-8 Method A.2 (Daisy Chain) for Shield Termination
190-01115-01
Rev. AA
G3X/G3X Touch Installation Manual - Connector Installation Instructions
Page 22-12