Installation - Beko Bekomat 14 Instructions For Installation And Operation Manual

Condensate drain
Table of Contents

Advertisement

Danger!
Compressed air!
Risk of serious injury or death through contact with quickly or suddenly escaping compressed air or
through bursting plant components or plant components which are not secured.
Measures:
• Do not exceed the maximum operating pressure (see type plate)!
• Only carry out service measures when the system is pressureless.
• Use pressure-resistant installation material only.
• The feed pipe must be tubed firmly. Discharge pipe: short, fixed pressure hose onto pressure-resistant pipe.
• Make sure that persons or objects cannot be hit by condensate or escaping compressed air.
Caution!
Malfunctions in the application!
Through incorrect installation and insufficient maintenance, the BEKOMAT can malfunction. Condensate
which is not discharged can lead to damage to plants and in manufacturing processes.
Measures:
• Fail-safe condensate discharge directly optimises the compressed-air quality.
• To prevent damage and failures, it is imperative
• To comply with the provisions regarding proper use and with the operating parameters of the BEKOMAT in connection
with the case of application (see chapter "Proper use").
• To strictly adhere to the installation and operating advice in these instructions.
• To maintain and check the BEKOMAT at regular intervals in accordance with the advice in these operating instructions.
Note:
It is imperative to observe all hazard statements and warnings listed here.
Please also observe all regulations and notes regarding the industrial safety and fire prevention at the respective place of

installation.

As a matter of principle, only use suitable and appropriate tools and materials in a proper condition.
Do not use aggressive cleaners and improper devices such as high-pressure cleaners.
Please note that condensates may contain aggressive or harmful components. Therefore, skin contact should be avoided.
Condensate is subject to mandatory waste disposal and must be collected in suitable
containers, and disposed of or processed properly.