Readings Gas parameter
Max.
L1 value:_____
Power
Min.
L2 value:_____
Power
Table 23
▶ Touch the symbol
▶ Close water taps.
CO
max. input
P1
min. input
P2
max. input
P1
min. input
P2
* Values above are for climate controlled conditions.
Inputs such as gas pressure, heating value of the gas,
humidity and temperature of combustion air all impact
CO and CO
values. Changes in these inputs can result in
2
different CO and CO
values on the same appliance.
2
Table 24 CO
& CO target numbers
2
CO
max. input
P1
min. input
P2
max. input
P1
10.1 % - 10.5 %
min. input
P2
* Values above are for climate controlled conditions.
Inputs such as gas pressure, heating value of the gas,
humidity and temperature of combustion air all impact
CO and CO
values. Changes in these inputs can result in
2
different CO and CO
values on the same appliance.
2
Table 25 CO
& CO target numbers
2
8.9.4 Returning to Service
▶ Remove the CO
analyzer probe and insert the screw into
2
the flue adaptor.
Greentherm 9800 SE 160/199 | SEC 199
Air Adjustment
A1 value:_____ CO
2
A2 value:_____ CO
2
.
range (%)
Max. CO level
2
(measured)
Greentherm 9800 SE / SEC
199 000 BTU
Nat. Gas
8.4 % - 8.8 %
< 250 ppm
2.5 % - 2.7 %
< 30 ppm
LP Gas
9.9 % - 10.3 %
< 250 ppm
2.9 % - 3.1 %
< 30 ppm
range (%)
Max. CO level
2
(measured)
Greentherm 9800 SE
160 000 BTU
Nat. Gas
8.7 % - 9.1 %
< 250 ppm
3.4 % - 3.6 %
< 30 ppm
LP Gas
< 250 ppm
3.8 % - 4.0 %
< 30 ppm
▶ Touch the symbol
The appliance is ready for normal operation.
value:_____
value:_____
Troubleshooting | 53
to return to main menu.
6 720 816 815 (2016/10)