Sym PA12B Service Manual page 83

Table of Contents

Advertisement

5. AC Generator / Starter Clutch
Precautions in Operation
General Information
For engine troubleshooting and inspection, please refer to the first chapter.
Starting Motor repairing process and cautions, please refer to Chapter 13
Specifications
Item
Start Driven Gear exterior diameter
Starting Clutch interior diameter
Torque Value
Flywheel Bolt
R crankcase cover bolts
Starting clutch inner-hexagon bolts 1.0~1.4kgf-m with screw adhesive
Special Tool
Flywheel puller
5-2
To this chapter contents
measurement:mm
Service Limit
54.060
54.940
5.0~6.0kgf-m
0.8~1.2kgf-m
SYM-3111000